PartsTable TECHNICAL DATA SHEET
NSN 5925-00-359-4001Government record, cited

Circuit Breaker5925-00-359-4001

NSN 5925-00-359-4001 · NIIN 003594001
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-359-4001 · 5925003594001 · NIIN 003594001 · 00-359-4001 · FSC 5925 Circuit Breakers · AP112RRR860-3 · 213967-1 · 213967-1 · AP112RRR860-1 · 213967-1
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.375 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC SECOND LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC THIRD LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
Identification
  • NSN: 5925-00-359-4001
  • NIIN: 003594001
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-359-4001, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-359-4001
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.375 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC SECOND LOCATION
Operating Voltage Type and Rating Per Pole in Volts50.0 DC THIRD LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationAT POLE TWO
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.625 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts50.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
Switch Location and Position DesignationINTERNAL AT EACH POLE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.937 INCHES MAXIMUM IN
Pole Quantity3
Mounting Surface to Terminal End Distance1.828 INCHES MAXIMUM IN
Thread Pitch Diameters+0.3503 TO 0.3537 INCHES IN
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC FIRST LOCATION
Maximum Continuous Load Current Rating Per Pole100.0 MILLIAMPERES DC THIRD LOCATION
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC SECOND LOCATION
Trip Release CharacteristicINSTANTANEOUS AND TIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC AND 500.0 DC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.562 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.007 MINIMUM AT 150 PCT AND 0.030 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps0.5 DC
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
AP112RRR860-3 5/2 Secondary reference
U.S. Government activity
213967-1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
213967-1 3/9 Design control — primary reference
Saga Engineering Corp
AP112RRR860-1 5/9 Secondary reference
U.S. Government activity
213967-1 5/9 Secondary reference
Data Products Corp
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-359-4001?

NSN 5925-00-359-4001 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-359-4001?

Key specifications for 5925-00-359-4001: Bushing Length: 0.375 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-359-4001 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com