PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

1357533Circuit Breaker

Westinghouse Electric Corp · NSN 5925-00-272-8959 · FSC 5925 · No Item Name Available
Verified by PartsTable
NSN 5925-00-272-8959 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-272-8959. Primary manufacturer part number: 1357533.
Features
  • Circuit Breaker — FSC 5925
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION
  • Trip Delay Time in Seconds Per Rated Continuous Current: 18.000 MINIMUM AT 200 PCT AND 33.000 MAXIMUM AT 200 PCT SINGLE LOCATION
  • Material: PLASTIC CASE
  • Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps: 5000.0 AC SINGLE LOCATION
  • Reset Method: MANUAL
  • Manual Actuator Type and Quantity: 1 TOGGLE
  • Frequency in Hertz: 60.0 SINGLE LOCATION
Applications
  • Applications requiring Plastic Case construction
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-272-8959, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Westinghouse Electric Corp. Government technical data includes 18 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 2 commercial cross-references from 1 manufacturer, enabling identification through both NSN and commercial part number lookups. 2 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-272-8959
Primary Part Number1357533
Item NameCircuit Breaker
FSC / FSG5925 / 59 — No Item Name Available
ManufacturerWestinghouse Electric Corp
StatusACTIVE
Operating Voltage Type and Rating Per Pole in Volts120.0 AC SINGLE LOCATION
Trip Delay Time in Seconds Per Rated Continuous Current18.000 MINIMUM AT 200 PCT AND 33.000 MAXIMUM AT 200 PCT SINGLE LOCATION
MaterialPLASTIC CASE
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC SINGLE LOCATION
Reset MethodMANUAL
Manual Actuator Type and Quantity1 TOGGLE
Frequency in Hertz60.0 SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Pole Quantity11
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S)2 UNTHREADED HOLE(S)
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC SINGLE LOCATION
Trip Release MethodTHERMAL SINGLE LOCATION
Actuator FunctionRESET
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Terminal Type and Quantity2 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Trip Release Ambient Temp Rating20.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 2
6670-01-383-7882100540 INTERCHANGEABLE
Computer Weighing Scale
Intercomp Co
4940-01-440-0879PT-20 INTERCHANGEABLE
Lid Assembly,paint
Smith Eastern Corp Div Airverter
Cross-Reference Index
Part NumberManufacturer
1357533 PRIMARY Westinghouse Electric Corp (USA)
PT20 PRIMARY Westinghouse Electric Corp (USA)
Related Parts
6670-01-383-7882INTERCHANGEABLE
COMPUTER WEIGHING SCALE
100540
4940-01-440-0879INTERCHANGEABLE
LID ASSEMBLY,PAINT
PT-20

Frequently Asked Questions

What is NSN 5925-00-272-8959?

NSN 5925-00-272-8959 is a Circuit Breaker, manufactured by Westinghouse Electric Corp, classified under FSC 5925 (No Item Name Available). Status: active.

What are the part numbers for NSN 5925-00-272-8959?

NSN 5925-00-272-8959 has 2 cross-referenced part numbers: 1357533 (Westinghouse Electric Corp), PT20 (Westinghouse Electric Corp).

What NSN replaces 5925-00-272-8959?

There are 2 known substitutes for 5925-00-272-8959: 6670-01-383-7882, 4940-01-440-0879. Verify interchangeability with system specifications before substitution.

What are the specifications of 1357533?

Key specifications for 1357533: Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC SINGLE LOCATION; Trip Delay Time in Seconds Per Rated Continuous Current: 18.000 MINIMUM AT 200 PCT AND 33.000 MAXIMUM AT 200 PCT SINGLE LOCATION; Material: PLASTIC CASE; Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps: 5000.0 AC SINGLE LOCATION. 18 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com