The Circuit Breaker, cataloged under National Stock Number 5925-00-260-4298, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-260-4298 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.390 INCHES MINIMUM AND 0.390 INCHES MINIMUM AND 0.565 INCHES MAXIMUM0.565 INCHES MAXIMUM IN |
| Reset Method | MANUALMANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING1 THREADED BUSHING |
| Actuator Position Designation | BETWEEN POLE ONE AND TWOBETWEEN POLE ONE AND TWO |
| Frequency in Hertz | 60.0 ALL LOCATIONS60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.625 INCHES NOMINAL0.625 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPEMULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS115.0 ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONSOVERCURRENT ALL LOCATIONS |
| Body Width | 1.281 INCHES MAXIMUM1.281 INCHES MAXIMUM IN |
| Pole Quantity | 22 |
| Mounting Surface to Terminal End Distance | 1.828 INCHES MAXIMUM1.828 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 18.0 AMPERES AC FIRST LOCATION18.0 AMPERES AC FIRST LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 250.0 MILLIAMPERES AC SECOND LOCATION250.0 MILLIAMPERES AC SECOND LOCATION |
| Trip Release Characteristic | INSTANTANEOUS AND INSTANTANEOUS AND TIME DELAY ALL LOCATIONSTIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC ALL LOCATIONS300.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES0.375 INCHES IN |
| Body Length | 1.562 INCHES MAXIMUM1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT AND 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS0.240 MAXIMUM AT 400 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE1 TOGGLE |
| Inclosure Protection Type for Which Designed | HERMETICALLY SEALEDHERMETICALLY SEALED |
| Thread Quantity Per Inch | 3232 |
| Actuator Function | TRIP-RESETTRIP-RESET |
| Terminal Type and Quantity | 4 WIRE HOOK4 WIRE HOOK |
| Main Contact Tripping Mechanism Type | TRIP FREETRIP FREE |
| Thread Series Designator | UNEFUNEF |
| Trip Release Method | MAGNETIC ALL LOCATIONSMAGNETIC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 0.875 INCHES NOMINAL0.875 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| AP12-1406-1 | 5/2 Secondary reference U.S. Government activity |
| 1730-2811 | 3/9 Design control — primary reference Lockheed Martin Corp Lockheed Martin Mission Systems |
| 78-166-1 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-00-260-4298 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-00-260-4298: Bushing Length: 0.390 INCHES MINIMUM AND 0.390 INCHES MINIMUM AND 0.565 INCHES MAXIMUM0.565 INCHES MAXIMUM IN; Reset Method: MANUALMANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONSSERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS240.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.