PartsTable TECHNICAL DATA SHEET
NSN 5925-00-254-2672Government record, cited

Circuit Breaker5925-00-254-2672

NSN 5925-00-254-2672 · NIIN 002542672
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-254-2672 · 5925002542672 · NIIN 002542672 · 00-254-2672 · FSC 5925 Circuit Breakers · MILC7079 · AN3161-35
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 30.0 DC SINGLE LOCATION
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 138.0 SINGLE LOCATION
  • Circuit Protection Type: OVERCURRENT SINGLE LOCATION
  • Pole Quantity: 1
  • Maximum Continuous Load Current Rating Per Pole: 35.0 AMPERES DC SINGLE LOCATION
  • Trip Release Characteristic: TIME DELAY SINGLE LOCATION
Identification
  • NSN: 5925-00-254-2672
  • NIIN: 002542672
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-254-2672, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 19 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-254-2672
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts30.0 DC SINGLE LOCATION
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole35.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2500.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Trip Delay Time in Seconds Per Rated Continuous Current100.000 MAXIMUM AT 200 PCT AND 10.000 MAXIMUM AT 400 PCT AND 3600.000 NOMINAL AT 138 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH BUTTON
Inclosure Protection Type for Which DesignedDUSTPROOF
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 SCREW
Main Contact Tripping Mechanism TypeNONTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Trip Release MethodTHERMAL SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MILC7079 4/1 Identification reference
U.S. Government activity
AN3161-35 2/2 Government specification standardization
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-254-2672?

NSN 5925-00-254-2672 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-254-2672?

Key specifications for 5925-00-254-2672: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 30.0 DC SINGLE LOCATION; Overall Height: 2.406 INCHES NOMINAL IN; Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 138.0 SINGLE LOCATION. 19 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-254-2672 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.