The Circuit Breaker, cataloged under National Stock Number 5925-00-220-3530, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-220-3530 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | RELAY TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 230.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 10 THREADED STUD(S) |
| Actuator Position Designation | BETWEEN POLE TWO AND THREE |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.750 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.062 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.530 INCHES MAXIMUM IN |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 2.658 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 200.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.125 INCHES IN |
| Body Length | 2.500 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.665 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP W/SEPARATE RESET |
| Terminal Type and Quantity | 7 THREADED STUD |
| Main Contact Tripping Mechanism Type | TRIP FREE AND NONTRIP FREE |
| Thread Series Designator | UNF |
| Boss Height | 0.140 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| SM-C-633334 | 3/2 Design control — primary reference U.S. Government activity |
| APL53-518-1 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-00-220-3530 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-00-220-3530: Reset Method: MANUAL; Internal Trip Release Configuration: RELAY TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 230.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 10 THREADED STUD(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.