The Circuit Breaker, cataloged under National Stock Number 5925-00-199-5858, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Cecom Lr Center. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 3 manufacturers, enabling identification through both NSN and commercial part number lookups. 4 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-199-5858 |
| Primary Part Number | 13216E0051 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Cecom Lr Center |
| Status | ACTIVE |
| Actuator Function | TRIP-RESET |
| Material | PLASTIC CASE |
| Nominal Thread Size | 0.138 INCHES IN |
| Terminal Type and Quantity | 9 THREADED STUD |
| Trip Delay Time in Seconds Per Rated Continuous Current | 50.000 MINIMUM AT 150 PCT AND 350.000 MAXIMUM AT 150 PCT ALL LOCATIONS |
| Actuator Position Designation | AT EACH POLE |
| Reset Method | MANUAL |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 3 TOGGLE |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Inclosure Protection Type for Which Designed | DUSTPROOF |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 3.546 INCHES NOMINAL IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Center to Center Distance Between Terminals Parallel to Width | 1.032 INCHES NOMINAL IN |
| Mounting Surface to Terminal End Distance | 2.609 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.032 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.750 INCHES NOMINAL IN |
| Special Handling Feature | MAGNETIC |
| Thread Quantity Per Inch | 32 |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) AND 6 SLOT |
| Pole Quantity | 3 |
| Fragility Factor | MODERATELY RUGGED |
| Boss Height | 0.218 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Internal Trip Release Configuration | SERIES TRIP W/DUAL RATING ALL LOCATIONS |
| Maximum Continuous Load Current Rating Per Pole | 26.0 AMPERES AC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 202850 | Triumph Thermal Systems - Maryland, Inc. (USA) |
| CD3-Z14-1 | Eaton Corp Heinemann Products Commercial Controls Div (USA) |
| CD3-Z40-1 | Eaton Corp Heinemann Products Commercial Controls Div (USA) |
| 13216E0051 PRIMARY | Cecom Lr Center (USA) |
NSN 5925-00-199-5858 is a Circuit Breaker, manufactured by Cecom Lr Center, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-00-199-5858 has 4 cross-referenced part numbers: 202850 (Triumph Thermal Systems - Maryland, Inc.), CD3-Z14-1 (Eaton Corp Heinemann Products Commercial Controls Div), CD3-Z40-1 (Eaton Corp Heinemann Products Commercial Controls Div), 13216E0051 (Cecom Lr Center).
There are 4 known substitutes for 5925-00-199-5858: 5325-00-402-4288, 5905-01-115-9362, 4820-01-280-8955 and 1 more. Verify interchangeability with system specifications before substitution.
Key specifications for 13216E0051: Actuator Function: TRIP-RESET; Material: PLASTIC CASE; Nominal Thread Size: 0.138 INCHES IN; Terminal Type and Quantity: 9 THREADED STUD. 30 total characteristics are documented in the Federal Logistics Information System.