PartsTable TECHNICAL DATA SHEET
NSN 5925-00-167-5475Government record, cited

Circuit Breaker5925-00-167-5475

NSN 5925-00-167-5475 · NIIN 001675475
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-167-5475 · 5925001675475 · NIIN 001675475 · 00-167-5475 · FSC 5925 Circuit Breakers · 578R330H05 · AP111R944-5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.330 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 240.0 DC ALL LOCATIONS
  • Actuator Position Designation: AT EACH POLE
  • Ultimate Trip Time Per Pole in Seconds: 0.200 MINIMUM AND 7.000 MAXIMUM ALL LOCATIONS
  • Switch Terminal Type: PIN
Identification
  • NSN: 5925-00-167-5475
  • NIIN: 001675475
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-167-5475, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-167-5475
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.330 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 240.0 DC ALL LOCATIONS
Actuator Position DesignationAT EACH POLE
Ultimate Trip Time Per Pole in Seconds0.200 MINIMUM AND 7.000 MAXIMUM ALL LOCATIONS
Switch Terminal TypePIN
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.625 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts120.0 AC AND 50.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Switch Location and Position DesignationEXTERNAL AT POLE THREE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.562 INCHES MAXIMUM IN
Pole Quantity3
Mounting Surface to Terminal End Distance1.828 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole240.0 MILLIAMPERES AC AND 240.0 MILLIAMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps240.0 AC AND 240.0 DC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.932 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.001 MINIMUM AT 400 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps0.5 AC AND 0.5 DC
Inclosure Protection Type for Which DesignedWEATHERPROOF
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
Thread Quantity Per Inch32
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
578R330H05 3/2 Design control — primary reference
U.S. Government activity
AP111R944-5 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-167-5475?

NSN 5925-00-167-5475 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-167-5475?

Key specifications for 5925-00-167-5475: Bushing Length: 0.330 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 240.0 DC ALL LOCATIONS. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-167-5475 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com