The Circuit Breaker, cataloged under National Stock Number 5925-00-159-0414, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-159-0414 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | AUTOMATIC |
| Operating Voltage Type and Rating Per Pole in Volts | 24.0 DC SINGLE LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Pole Quantity | 1 |
| Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1500.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 9.000 NOMINAL AT 300 PCT AND 3.500 NOMINAL AT 500 PCT SINGLE LOCATION |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Terminal Type and Quantity | 2 SCREW |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Hazardous per DLA record (HMIC Y) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 8751K4 | 5/9 Secondary reference Eaton Corp Opns & Technical Center |
| 8751K4 | 3/9 Design control — primary reference U.S. Government activity |
NSN 5925-00-159-0414 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-00-159-0414: Reset Method: AUTOMATIC; Operating Voltage Type and Rating Per Pole in Volts: 24.0 DC SINGLE LOCATION; Overall Height: 2.875 INCHES NOMINAL IN; Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 138.0 SINGLE LOCATION. 16 specifications are documented in the U.S. Government catalog.
Hazardous per DLA record (HMIC Y). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.