PartsTable TECHNICAL DATA SHEET
NSN 5925-00-155-2587Government record, cited

Circuit Breaker5925-00-155-2587

NSN 5925-00-155-2587 · NIIN 001552587 · Part number AM3R-A3A16-LC070A-16-1
Heinemann Electric Canada Incdivision of Eaton Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE L3330
Government record, cited
NSN 5925-00-155-2587 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-155-2587. Manufacturer of record part number: AM3R-A3A16-LC070A-16-1.
Also searched as  5925-00-155-2587 · 5925001552587 · NIIN 001552587 · 00-155-2587 · FSC 5925 Circuit Breakers · CAGE L3330 · AM3R-A3A16-LC070A-16-1 · 128C188H15 · APL-111-1A · APL-111-1-42-183-M · AM3A3A3A16
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Unpackaged Unit Weight: 11.100 OUNCES NOMINAL OZ
Identification
  • NSN: 5925-00-155-2587
  • NIIN: 001552587
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: AM3R-A3A16-LC070A-16-1
  • Manufacturer: Heinemann Electric Canada Incdivision of Eaton Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-155-2587, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Heinemann Electric Canada Incdivision of Eaton Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-155-2587
Primary Part NumberAM3R-A3A16-LC070A-16-1
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerHeinemann Electric Canada Incdivision of Eaton Corp
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Frequency in Hertz400.0 ALL LOCATIONS
Unpackaged Unit Weight11.100 OUNCES NOMINAL OZ
Center to Center Distance Between Terminals Parallel to Width0.750 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.250 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance2.475 INCHES NOMINAL IN
Thread Pitch Diameters+0.1177 TO 0.1214 INCHES IN
Maximum Continuous Load Current Rating Per Pole18.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MINIMUM AT 200 PCT AND 22.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity3 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.750 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
Thread Quantity Per Inch32
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-056-760820L4-103 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)Ellis & Watts International, Llc
Cross-Reference Index
Part NumberManufacturer
AM3R-A3A16-LC070A-16-1 Heinemann Electric Canada Incdivision of Eaton Corp (CAN)
Reference documents
ReferenceMeaning
128C188H15 3/2 Design control — primary reference
U.S. Government activity
APL-111-1A 5/9 Secondary reference
U.S. Government activity
APL-111-1-42-183-M 5/2 Secondary reference
U.S. Government activity
AM3A3A3A16 C/1 Advisory reference — outside the item-of-supply concept
Eaton Corp Heinemann Products Commercial Controls Div
AM333MG6-18-250VAC-15-400HZ 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
AM333MG6 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
Related Parts
5925-01-056-7608POSSIBLE MATCH
CIRCUIT BREAKER
20L4-103

Frequently Asked Questions

What is NSN 5925-00-155-2587?

NSN 5925-00-155-2587 is a Circuit Breaker, manufactured by Heinemann Electric Canada Incdivision of Eaton Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-155-2587?

NSN 5925-00-155-2587 has 1 manufacturer part number on file: AM3R-A3A16-LC070A-16-1 (Heinemann Electric Canada Incdivision of Eaton Corp).

What NSN replaces 5925-00-155-2587?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-056-7608. Verify interchangeability with system specifications before substitution.

What are the specifications of AM3R-A3A16-LC070A-16-1?

Key specifications for AM3R-A3A16-LC070A-16-1: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-155-2587 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.