The Circuit Breaker, cataloged under National Stock Number 5925-00-144-0459, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is B E Aerospace Inc Jacksonville Facility Dba Nordskog Industries. Government technical data includes 28 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 3 commercial cross-references from 2 manufacturers, enabling identification through both NSN and commercial part number lookups. 4 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5925-00-144-0459 |
| Primary Part Number | 49292 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | B E Aerospace Inc Jacksonville Facility Dba Nordskog Industries |
| Status | CANCELLED |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 900.0 DC SINGLE LOCATION |
| Actuator Position Designation | AT POLE ONE |
| Terminal Type and Quantity | 2 SCREW |
| Operating Voltage Type and Rating Per Pole in Volts | 30.0 DC SINGLE LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 120.0 AMPERES DC SINGLE LOCATION |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 30.000 NOMINAL AT 200 PCT SINGLE LOCATION |
| Nominal Thread Size | 0.164 INCHES IN |
| Pole Quantity | 1 |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.813 INCHES NOMINAL IN |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Center to Center Distance Between Terminals Parallel to Length | 1.438 INCHES NOMINAL IN |
| Mounting Surface to Terminal End Distance | 2.031 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.781 INCHES NOMINAL IN |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Body Width | 1.547 INCHES NOMINAL IN |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Material | PLASTIC CASE |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Reset Method | MANUAL |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 49292 | B E Aerospace Inc Jacksonville Facility Dba Nordskog Industries (USA) |
| D636458-11 | Sensata Technologies, Inc. Div Sensata Attleboro (USA) |
| D6364-1-120 | Sensata Technologies, Inc. Div Sensata Attleboro (USA) |
NSN 5925-00-144-0459 is a Circuit Breaker, manufactured by B E Aerospace Inc Jacksonville Facility Dba Nordskog Industries, classified under FSC 5925 (No Item Name Available). Status: cancelled.
NSN 5925-00-144-0459 has 3 cross-referenced part numbers: 49292 (B E Aerospace Inc Jacksonville Facility Dba Nordskog Industries), D636458-11 (Sensata Technologies, Inc. Div Sensata Attleboro), D6364-1-120 (Sensata Technologies, Inc. Div Sensata Attleboro).
There are 4 known substitutes for 5925-00-144-0459: 5330-00-171-7835, 5975-00-844-1066, 6150-01-079-4498 and 1 more. Verify interchangeability with system specifications before substitution.
Key specifications for 49292: Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps: 900.0 DC SINGLE LOCATION; Actuator Position Designation: AT POLE ONE; Terminal Type and Quantity: 2 SCREW; Operating Voltage Type and Rating Per Pole in Volts: 30.0 DC SINGLE LOCATION. 29 total characteristics are documented in the Federal Logistics Information System.
NSN 5925-00-144-0459 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.