PartsTable TECHNICAL DATA SHEET
NSN 5925-00-106-7253Government record, cited

Circuit Breaker5925-00-106-7253

NSN 5925-00-106-7253 · NIIN 001067253
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-00-106-7253 · 5925001067253 · NIIN 001067253 · 00-106-7253 · FSC 5925 Circuit Breakers · S451D859G01 · EH3015A · EHB3015A
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 480.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.375 INCHES NOMINAL IN
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-00-106-7253
  • NIIN: 001067253
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-106-7253, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-106-7253
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts480.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE TWO
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.375 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length4.500 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width4.125 INCHES NOMINAL IN
Body Height3.375 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.187 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS AND TIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps15000.0 AC ALL LOCATIONS
Body Length6.000 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current55.000 MINIMUM AT 200 PCT AND 90.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.375 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 COMPRESSION
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.125 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
S451D859G01 5/9 Secondary reference
Westinghouse Electric Corp Control Business Unit
EH3015A 5/9 Secondary reference
Westinghouse Electric Corp Control Business Unit
EHB3015A 3/9 Design control — primary reference
Westinghouse Electric Corp Control Business Unit
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-106-7253?

NSN 5925-00-106-7253 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-00-106-7253?

Key specifications for 5925-00-106-7253: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 480.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-106-7253 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com