The Circuit Breaker, cataloged under National Stock Number 5925-00-061-3209, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is British Sarozal Ltd. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 6 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-061-3209 |
| Primary Part Number | BS-7274-2-15 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | British Sarozal Ltd |
| Status | ACTIVE |
| Bushing Length | 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 200.0 AC AND 28.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 38.0 GRAMS NOMINAL G |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 145.0 SINGLE LOCATION |
| Arc Quenching Method | AIR |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.919 INCHES MINIMUM AND 1.981 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND 5.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC AND 5000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.469 INCHES IN |
| Body Length | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Inclosure Protection Type for Which Designed | VIBRATIONPROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Terminal Type and Quantity | 2 TAB W/SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| BS-7274-2-15 | British Sarozal Ltd (GBR) |
| Reference | Meaning |
|---|---|
| 7274-21-5 | 5/9 Secondary reference U.S. Government activity |
| 7274-21-1/2 | 5/9 Secondary reference U.S. Government activity |
| BACC18U1/2 | 5/2 Secondary reference U.S. Government activity |
| BACC18U5 | 5/9 Secondary reference U.S. Government activity |
| BACC18U1/2 | 3/2 Design control — primary reference U.S. Government activity |
| BACC18U05 | 5/9 Secondary reference U.S. Government activity |
NSN 5925-00-061-3209 is a Circuit Breaker, manufactured by British Sarozal Ltd, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-061-3209 has 1 manufacturer part number on file: BS-7274-2-15 (British Sarozal Ltd).
2 possible matches (shared part number, not a government interchangeability claim): 5925-00-820-5347, 5925-00-890-4340. Verify interchangeability with system specifications before substitution.
Key specifications for BS-7274-2-15: Bushing Length: 0.219 INCHES MINIMUM AND 0.281 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 28.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.