PartsTable TECHNICAL DATA SHEET
NSN 5925-00-050-7649Government record, cited

Circuit Breaker5925-00-050-7649

NSN 5925-00-050-7649 · NIIN 000507649 · Part number 328C055H07
Westinghouse Electric Corp · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 79500
Government record, cited
NSN 5925-00-050-7649 — this item is cataloged by the U.S. Government under National Stock Number 5925-00-050-7649. Manufacturer of record part number: 328C055H07.
Also searched as  5925-00-050-7649 · 5925000507649 · NIIN 000507649 · 00-050-7649 · FSC 5925 Circuit Breakers · CAGE 79500 · 328C055H07 · AM30MG6-10A
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Switch Terminal Type: THREADED STUD
  • Frequency in Hertz: 400.0 SINGLE LOCATION
Identification
  • NSN: 5925-00-050-7649
  • NIIN: 000507649
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 328C055H07
  • Manufacturer: Westinghouse Electric Corp
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-00-050-7649, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Westinghouse Electric Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-00-050-7649
Primary Part Number328C055H07
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerWestinghouse Electric Corp
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Switch Terminal TypeTHREADED STUD
Frequency in Hertz400.0 SINGLE LOCATION
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Switch Voltage Rating and Type in Volts250.0 AC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Switch Location and Position DesignationEXTERNAL AT POLE ONE
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN
Pole Quantity1
Mounting Surface to Terminal End Distance2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current1.500 MINIMUM AT 200 PCT AND 7.500 MAXIMUM AT 200 PCT SINGLE LOCATION
Switch Current Rating and Type in Amps10.0 AC
Inclosure Protection Type for Which DesignedDUSTPROOF
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
328C055H07 Westinghouse Electric Corp (USA)
Reference documents
ReferenceMeaning
AM30MG6-10A 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
328C055H07 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-00-050-7649?

NSN 5925-00-050-7649 is a Circuit Breaker, manufactured by Westinghouse Electric Corp, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-00-050-7649?

NSN 5925-00-050-7649 has 1 manufacturer part number on file: 328C055H07 (Westinghouse Electric Corp).

What are the specifications of 328C055H07?

Key specifications for 328C055H07: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-00-050-7649 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.