The Circuit Breaker, cataloged under National Stock Number 5925-00-023-0104, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Safran Power Usa, Llc. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 1 verified substitute exists in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-023-0104 |
| Primary Part Number | 700-015-7 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Safran Power Usa, Llc |
| Status | ACTIVE |
| Nominal Thread Size | 0.469 INCHES IN |
| Actuator Function | TRIP-RESET |
| Actuator Position Designation | AT POLE ONE |
| Body Width | 0.740 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Center to Center Distance Between Terminals Parallel to Length | 0.704 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Mounting Surface to Terminal End Distance | 1.812 INCHES MAXIMUM IN |
| Thread Quantity Per Inch | 32 |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Pole Quantity | 1 |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 11.000 MINIMUM AT 200 PCT AND 90.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Material | PLASTIC CASE |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Inclosure Protection Type for Which Designed | DUSTPROOF |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL SINGLE LOCATION DEGC |
| Terminal Type and Quantity | 2 SCREW |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Maximum Continuous Load Current Rating Per Pole | 7.5 AMPERES AC AND 7.5 AMPERES DC SINGLE LOCATION |
| Reset Method | MANUAL |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Bushing Length | 0.250 INCHES NOMINAL IN |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2000.0 AC AND 2000.0 DC SINGLE LOCATION |
| Body Length | 1.094 INCHES MAXIMUM IN |
| Body Style | SINGLE POLE TYPE |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 28.0 DC SINGLE LOCATION |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 2107D | Wood Electric Operations Potter and Brumfield Div Amf Inc (USA) |
| 740034-3 | Lockheed Martin Corp (USA) |
| 254-507-102 | Te Connectivity Corporation (USA) |
| 700-015-7 PRIMARY | Safran Power Usa, Llc (USA) |
NSN 5925-00-023-0104 is a Circuit Breaker, manufactured by Safran Power Usa, Llc, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-00-023-0104 has 4 cross-referenced part numbers: 2107D (Wood Electric Operations Potter and Brumfield Div Amf Inc), 740034-3 (Lockheed Martin Corp), 254-507-102 (Te Connectivity Corporation), 700-015-7 (Safran Power Usa, Llc).
There is 1 known substitute for 5925-00-023-0104: 6240-00-782-5991. Verify interchangeability with system specifications before substitution.
Key specifications for 700-015-7: Nominal Thread Size: 0.469 INCHES IN; Actuator Function: TRIP-RESET; Actuator Position Designation: AT POLE ONE; Body Width: 0.740 INCHES MAXIMUM IN. 30 total characteristics are documented in the Federal Logistics Information System.