The Circuit Breaker, cataloged under National Stock Number 5925-00-007-0940, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Getronics Government Solutions Llc. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-007-0940 |
| Primary Part Number | 70960056-001 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Getronics Government Solutions Llc |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 20.0 DC SECOND LOCATION |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60.0 FIRST LOCATION |
| Center to Center Distance Between Terminals Parallel to Width | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.655 INCHES MINIMUM AND 1.655 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.468 INCHES MINIMUM AND 1.532 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES AC FIRST LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 50.0 MILLIAMPERES DC SECOND LOCATION |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC FIRST LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 DC SECOND LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM IN |
| Inclosure Protection Type for Which Designed | DUSTPROOF |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 70960056-001 PRIMARY | Getronics Government Solutions Llc (USA) |
| Reference | Meaning |
|---|---|
| APG14-30A250V60D61RT50MA20VDCD50 | 5/9 Secondary reference U.S. Government activity |
| 70960056-001 | 5/9 Secondary reference Bull Hn Information Systems Inc |
| UPGH41-743-2 | 5/2 Secondary reference U.S. Government activity |
| JA2A3B6L30-250V60C3R0-050-20VDCP | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| JA2A3B6B | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-00-007-0940 is a Circuit Breaker, manufactured by Getronics Government Solutions Llc, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-00-007-0940 has 1 manufacturer part number on file: 70960056-001 (Getronics Government Solutions Llc).
Key specifications for 70960056-001: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC FIRST LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 20.0 DC SECOND LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.