The Circuit Breaker, cataloged under National Stock Number 5925-00-005-3115, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Eaton Corporation Dba Eaton Inoac. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 7 commercial cross-references from 2 manufacturers, enabling identification through both NSN and commercial part number lookups. 5 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-00-005-3115 |
| Primary Part Number | 6601C86G12 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Eaton Corporation Dba Eaton Inoac |
| Status | ACTIVE |
| Body Width | 4.125 INCHES NOMINAL IN |
| Unthreaded Mounting Hole Diameter | 0.187 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 4.500 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.375 INCHES NOMINAL IN |
| Features Provided | ADJUSTABLE TRIP RELEASE |
| Center to Center Distance Between Terminals Parallel to Width | 1.375 INCHES NOMINAL IN |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Center to Center Distance Between Terminals Parallel to Length | 5.062 INCHES NOMINAL IN |
| Boss Height | 0.125 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Actuator Function | TRIP-RESET |
| Material | PLASTIC CASE |
| Adjustable Trip Setting Current Range Per Pole in Amps | +450.0 TO 825.0 AC ALL LOCATIONS |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Actuator Position Designation | AT POLE TWO |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Terminal Type and Quantity | 6 COMPRESSION |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Reset Method | MANUAL |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Length | 6.000 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 150.0 AMPERES AC ALL LOCATIONS |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 600.0 AC ALL LOCATIONS |
| Body Height | 3.375 INCHES NOMINAL IN |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 2606D97G28 | Eaton Corporation Dba Eaton Inoac (USA) |
| 6601C86G12 PRIMARY | Eaton Corporation Dba Eaton Inoac (USA) |
| MCP431550 | Eaton Corporation Dba Eaton Inoac (USA) |
| 4994D97G28 | Eaton Corporation Dba Eaton Inoac (USA) |
| 23740 | Erie Strayer Co (USA) |
| MCP431550R | Eaton Corporation Dba Eaton Inoac (USA) |
| 6630C86G21 | Eaton Corporation Dba Eaton Inoac (USA) |
NSN 5925-00-005-3115 is a Circuit Breaker, manufactured by Eaton Corporation Dba Eaton Inoac, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-00-005-3115 has 7 cross-referenced part numbers: 2606D97G28 (Eaton Corporation Dba Eaton Inoac), 6601C86G12 (Eaton Corporation Dba Eaton Inoac), MCP431550 (Eaton Corporation Dba Eaton Inoac), 4994D97G28 (Eaton Corporation Dba Eaton Inoac), 23740 (Erie Strayer Co) and 2 more.
There are 5 known substitutes for 5925-00-005-3115: 5985-00-179-7903, 5826-00-977-2759, 3030-01-272-7604 and 2 more. Verify interchangeability with system specifications before substitution.
Key specifications for 6601C86G12: Body Width: 4.125 INCHES NOMINAL IN; Unthreaded Mounting Hole Diameter: 0.187 INCHES NOMINAL IN; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 4.500 INCHES NOMINAL IN; Distance Between Centerlines of Mounting Facilities Parallel to Body Width: 1.375 INCHES NOMINAL IN. 30 total characteristics are documented in the Federal Logistics Information System.