The Fuse,enclosed Link, cataloged under National Stock Number 5920-01-309-1544, is classified within Federal Supply Class 5920 (Fuses, Arrestors, Absorbers, and Protectors) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Cegelec Ndt-Psc. Government technical data includes 5 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5920-01-309-1544 |
| Primary Part Number | 48-572409 |
| Item Name | Fuse,enclosed Link |
| FSC / FSG | 5920 / 59 — Fuses, Arrestors, Absorbers, and Protectors |
| Manufacturer | Cegelec Ndt-Psc |
| Status | ACTIVE |
| Continuous Current Rating in Amps | 63.000 |
| Fragility Factor | MODERATELY RUGGED |
| Interruption Indicator Method | TERMINAL-VISUAL OR ALARM |
| Maximum Voltage Rating in Volts | 750.0 DC |
| Circuit Over-Current Interruption Type | NORMAL INSTANTANEOUS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 48-572409 | Cegelec Ndt-Psc (FRA) |
| Reference | Meaning |
|---|---|
| 48-572409 | 5/9 Secondary reference Cegelec Division Dei |
| RC-750 VDC | C/1 Advisory reference — outside the item-of-supply concept Mersen France Sb SAS |
| CC7 BODK C3 RC 120 TTC 63A | 3/9 Design control — primary reference Carbone-Ferraz Inc |
NSN 5920-01-309-1544 is a Fuse,enclosed Link, manufactured by Cegelec Ndt-Psc, classified under FSC 5920, Fuses, Arrestors, Absorbers, and Protectors. Status: active.
NSN 5920-01-309-1544 has 1 manufacturer part number on file: 48-572409 (Cegelec Ndt-Psc).
Key specifications for 48-572409: Continuous Current Rating in Amps: 63.000; Fragility Factor: MODERATELY RUGGED; Interruption Indicator Method: TERMINAL-VISUAL OR ALARM; Special Features: FUSIBLE ELEMENT NONRENEWABLE. 5 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.