The Fuseholder,block, cataloged under National Stock Number 5920-01-189-5288, is classified within Federal Supply Class 5920 (Fuses, Arrestors, Absorbers, and Protectors) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Dba Raytheon Co. Government technical data includes 12 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5920-01-189-5288 |
| Primary Part Number | 928962-1 |
| Item Name | Fuseholder,block |
| FSC / FSG | 5920 / 59 — Fuses, Arrestors, Absorbers, and Protectors |
| Manufacturer | Raytheon Company Dba Raytheon Co |
| Status | ACTIVE |
| Accommodated Fuse Length | 1.250 INCHES NOMINAL IN |
| Internal Circuit Configuration and Pole Quantity | 5 POLE, MAINLINE, FUSED |
| Coating Method | PLATED CONTACT |
| Voltage in Volts | 250.0 |
| Accommodated Ferrule Diameter | 0.250 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN |
| Fuse Terminal Type Accommodated | FERRULE |
| Surface Treatment | NICKEL CONTACT |
| Current Carrying Rating in Amps | 30.0 |
| Material | COPPER CONTACT |
| Material | PLASTIC BODY |
| Terminal Type and Quantity | 10 TAB, SOLDER LUG |
| Fuse Accommodation Quantity | 5 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
NSN 5920-01-189-5288 is a Fuseholder,block, manufactured by Raytheon Company Dba Raytheon Co, classified under FSC 5920, Fuses, Arrestors, Absorbers, and Protectors. Status: active.
NSN 5920-01-189-5288 has 2 manufacturer part numbers on file: 928962-1 (Raytheon Company), 928962-1 (Raytheon Company Dba Raytheon Co).
Key specifications for 928962-1: Accommodated Fuse Length: 1.250 INCHES NOMINAL IN; Internal Circuit Configuration and Pole Quantity: 5 POLE, MAINLINE, FUSED; Coating Method: PLATED CONTACT; Voltage in Volts: 250.0. 12 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.