The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-392-6246, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-392-6246 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | HERMETICALLY SEALED |
| Power Line Frequency Rating Per Function in Hertz | 400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| Body Outside Diameter | 0.416 INCHES MAXIMUM IN |
| Source Impedance Rating Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Maximum Voltage Drop Per Function | 0.25 VOLTS AC BLANK AND 0.25 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Style Designator | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Mounting Facility Screw Thread Series Designator | UNF |
| Features Provided | SHOCK RESISTANT AND MOISTURE RESISTANT |
| Nominal Thread Size | 0.250 INCHES IN |
| Specification/standard Data | 81349-MIL-F-15733/59 GOVERNMENT SPECIFICATION |
| Body Material | METAL |
| Body Length | 0.598 INCHES NOMINAL IN |
| Full Load Insertion Loss Frequencies in Megahertz | 0.15 AND 0.3 AND 1.0 AND 10.0 AND 1000.0 |
| Full Load Minimum Insertion Loss at Specified Frequency in Decibels | 12.0 AND 23.0 AND 44.0 AND 70.0 |
| Operating Voltage Rating and Type Per Function | 150.0 VOLTS AC BLANK AND 200.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Principal Circuitry Type Per Function | CAPACITANCE-INDUCTANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Current Rating Per Function in Amps | 1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Temp Range | -55.0 TO 125.0 CELSIUS DEGC |
| Test Data Document | 81349-MIL-F-15733 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Maximum Temp Rise | 7.0 CELSIUS DEGC |
| Load Impedance Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL Q — CCL Item — Commerce Control List |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| M15733/59-0001 | 2/2 Government specification standardization U.S. Government activity |
| MIL-PRF-15733/59 | 4/1 Identification reference U.S. Government activity |
| MIL-F-15733/59 | 5/9 Secondary reference U.S. Government activity |
NSN 5915-01-392-6246 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.
1 possible match (shared part number, not a government interchangeability claim): 5915-01-406-7643. Verify interchangeability with system specifications before substitution.
Key specifications for 5915-01-392-6246: Mounting Facility Type and Quantity: 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: HERMETICALLY SEALED; Power Line Frequency Rating Per Function in Hertz: 400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED; Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG INPUT FIRST FUNCTION. 24 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
NSN 5915-01-392-6246 has DEMIL Code Q. Demilitarization may be required before disposal or transfer to non-military entities.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.