The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-386-7171, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 10 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-386-7171 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 1 TERMINAL LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | HERMETICALLY SEALED |
| Power Line Frequency Rating Per Function in Hertz | 60.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Functional Terminal Type and Quantity | 1 THREADED STUD INPUT FIRST FUNCTION |
| Body Outside Diameter | 0.670 INCHES NOMINAL IN |
| Source Impedance Rating Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Style Designator | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Operating Voltage Rating and Type Per Function | 30.0 VOLTS AC BLANK AND 100.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Current Rating Per Function in Amps | 1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Temp Range | -55.0 TO 85.0 CELSIUS DEGC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| GF4200-4 | 5/9 Secondary reference Genisco Filter Corp |
| GF4200-4 | 3/9 Design control — primary reference Spectrum Control, Inc. Div Api Technologies - Eis/wesson |
NSN 5915-01-386-7171 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-01-386-7171: Mounting Facility Type and Quantity: 1 TERMINAL LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: HERMETICALLY SEALED; Power Line Frequency Rating Per Function in Hertz: 60.0 BLANK LOCATION NOT OTHERWISE SPECIFIED; Functional Terminal Type and Quantity: 1 THREADED STUD INPUT FIRST FUNCTION. 10 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.