PartsTable TECHNICAL DATA SHEET
NSN 5915-01-360-5093Government record, cited

Filter, Radio Frequency Interfere5915-01-360-5093

NSN 5915-01-360-5093 · NIIN 013605093 · Part number 9135-0325
Keysight Technologies Inc · FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components · CAGE 7ZXR5
Government record, cited
NSN 5915-01-360-5093 — this item is cataloged by the U.S. Government under National Stock Number 5915-01-360-5093. Manufacturer of record part number: 9135-0325.
Also searched as  5915-01-360-5093 · 5915013605093 · NIIN 013605093 · 01-360-5093 · FSC 5915 Filters and Networks · CAGE 7ZXR5 · 9135-0325 · FN393-2,5-05-12 · 5062-7349
Nearby stock numbers  ·
Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Power Line Frequency Rating Per Function in Hertz: 60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Functional Terminal Type and Quantity: 2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG GROUND THIRD FUNCTION
  • Functional Terminal Type and Quantity: 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
Identification
  • NSN: 5915-01-360-5093
  • NIIN: 013605093
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 9135-0325
  • Manufacturer: Keysight Technologies Inc
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-360-5093, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Keysight Technologies Inc. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-01-360-5093
Primary Part Number9135-0325
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
ManufacturerKeysight Technologies Inc
StatusACTIVE
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Power Line Frequency Rating Per Function in Hertz60.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Power Line Frequency Rating Per Function in Hertz60.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Functional Terminal Type and Quantity2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity1 TAB, SOLDER LUG GROUND THIRD FUNCTION
Functional Terminal Type and Quantity1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Body Width1.000 INCHES NOMINAL IN
Body Height2.561 INCHES NOMINAL IN
Unthreaded Mounting Hole Diameter0.100 INCHES NOMINAL IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
Body MaterialALUMINUM
Body Length3.000 INCHES NOMINAL IN
Operating Voltage Rating and Type Per Function250.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Voltage Rating and Type Per Function250.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Current Rating Per Function in Amps2.5 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Current Rating Per Function in Amps2.5 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Temp Range-25.0 TO 85.0 CELSIUS DEGC
Load Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Load Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
FN393-2,5-05-12 Schaffner Emv Ag (CHE)
9135-0325 PRIMARY Keysight Technologies Inc (USA)
Reference documents
ReferenceMeaning
9135-0325 5/9 Secondary reference
Hewlett-Packard Company Dba HP
5062-7349 5/9 Secondary reference
Agilent Technologies Inc. Div Agilent Solution Support
9135-0325 3/9 Design control — primary reference
Keysight Technologies, Inc.
FN393-2,5-06-12 5/9 Secondary reference
Schaffner Emv Ag
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-01-360-5093?

NSN 5915-01-360-5093 is a Filter,radio Frequency Interfere, manufactured by Keysight Technologies Inc, classified under FSC 5915, Filters and Networks. Status: active.

What part numbers are listed for NSN 5915-01-360-5093?

NSN 5915-01-360-5093 has 2 manufacturer part numbers on file: FN393-2,5-05-12 (Schaffner Emv Ag), 9135-0325 (Keysight Technologies Inc).

What are the specifications of 9135-0325?

Key specifications for 9135-0325: Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: HERMETICALLY SEALED; Power Line Frequency Rating Per Function in Hertz: 60.0 2ND RADIO INTERFERENCE SECOND FUNCTION; Power Line Frequency Rating Per Function in Hertz: 60.0 1ST RADIO INTERFERENCE FIRST FUNCTION. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5915-01-360-5093 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com