The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-336-3010, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Ge Aviation Systems Llc. Government technical data includes 27 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-336-3010 |
| Primary Part Number | 108798-001 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Manufacturer | Ge Aviation Systems Llc |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | ENCASED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.312 INCHES NOMINAL IN |
| Power Line Frequency Rating Per Function in Hertz | 50.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Power Line Frequency Rating Per Function in Hertz | 50.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Functional Terminal Type and Quantity | 2 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| Functional Terminal Type and Quantity | 2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG GROUND THIRD FUNCTION |
| Source Impedance Rating Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Vibration Resistance Range in Hertz | +5.0 TO 200.0 |
| Body Width | 1.438 INCHES NOMINAL IN |
| Body Height | 1.375 INCHES NOMINAL IN |
| Unthreaded Mounting Hole Diameter | 0.249 INCHES MINIMUM AND 0.255 INCHES MAXIMUM IN |
| Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Features Provided | SHOCK RESISTANT |
| Body Material | METAL |
| Body Length | 2.000 INCHES NOMINAL IN |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC 1ST RADIO INTERFERENCE AND 100.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC 2ND RADIO INTERFERENCE AND 100.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Operating Current Rating Per Function in Amps | 4.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Operating Current Rating Per Function in Amps | 4.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Operating Temp Range | -46.0 TO 59.0 CELSIUS DEGC |
| Maximum Temp Rise | 75.0 CELSIUS DEGC |
| Load Impedance Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 108798-001 PRIMARY | Ge Aviation Systems Llc (USA) |
| Reference | Meaning |
|---|---|
| 108681 | 5/9 Secondary reference Ge Aviation Systems Llc Dba Ge Aviation |
| 108681 | 5/1 Secondary reference Ge Aviation Systems Llc |
| 108798-001 | 5/9 Secondary reference Ge Aviation Systems Llc Dba Ge Aviation |
NSN 5915-01-336-3010 is a Filter,radio Frequency Interfere, manufactured by Ge Aviation Systems Llc, classified under FSC 5915, Filters and Networks. Status: active.
NSN 5915-01-336-3010 has 1 manufacturer part number on file: 108798-001 (Ge Aviation Systems Llc).
Key specifications for 108798-001: Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: ENCASED; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.312 INCHES NOMINAL IN; Power Line Frequency Rating Per Function in Hertz: 50.0 2ND RADIO INTERFERENCE SECOND FUNCTION. 27 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.