PartsTable TECHNICAL DATA SHEET
NSN 5915-01-226-8397Government record, cited

Filter, Radio Frequency Interfere5915-01-226-8397

NSN 5915-01-226-8397 · NIIN 012268397
FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5915-01-226-8397 · 5915012268397 · NIIN 012268397 · 01-226-8397 · FSC 5915 Filters and Networks · SCD51990337-001 · RF3708-1
Nearby stock numbers  ·
Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Maximum Dielectric Withstanding DC Voltage: 800.0 VOLTS AT SEA LEVEL
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: ENCASED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.890 INCHES MAXIMUM IN
  • Power Line Frequency Rating Per Function in Hertz: 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Identification
  • NSN: 5915-01-226-8397
  • NIIN: 012268397
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-226-8397, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-01-226-8397
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Maximum Dielectric Withstanding DC Voltage800.0 VOLTS AT SEA LEVEL
Mounting Facility Type and Quantity4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeENCASED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.890 INCHES MAXIMUM IN
Power Line Frequency Rating Per Function in Hertz400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Functional Terminal Type and Quantity3 THREADED STUD OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity3 THREADED STUD INPUT FIRST FUNCTION
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Vibration Resistance Range in Hertz+10.0 TO 500.0
Body Width1.160 INCHES MAXIMUM IN
Body Height3.610 INCHES MAXIMUM IN
Maximum Voltage Drop Per Function1.15 VOLTS AC 1ST RADIO INTERFERENCE AND 4.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
Maximum Voltage Drop Per Function1.15 VOLTS AC 2ND RADIO INTERFERENCE AND 4.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
Maximum Voltage Drop Per Function1.15 VOLTS AC 3RD RADIO INTERFERENCE AND 4.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
Mounting Facility Screw Thread Series DesignatorUNF
Nominal Thread Size0.190 INCHES IN
Body MaterialMETAL
Body Length3.410 INCHES MAXIMUM IN
Operating Voltage Rating and Type Per Function115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Voltage Rating and Type Per Function115.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Voltage Rating and Type Per Function115.0 VOLTS AC 3RD RADIO INTERFERENCE AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.640 INCHES MAXIMUM IN
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL D — Destroy Item
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
SCD51990337-001 3/9 Design control — primary reference
Peraton Inc
RF3708-1 5/9 Secondary reference
Ems Development Corporation Dba Ems Development Corp
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-01-226-8397?

NSN 5915-01-226-8397 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-01-226-8397?

Key specifications for 5915-01-226-8397: Maximum Dielectric Withstanding DC Voltage: 800.0 VOLTS AT SEA LEVEL; Mounting Facility Type and Quantity: 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 4.990 INCHES MAXIMUM IN; Inclosure Type: ENCASED. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5915-01-226-8397 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5915-01-226-8397?

NSN 5915-01-226-8397 has DEMIL Code D. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com