Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Maximum Dielectric Withstanding DC Voltage: 375.0 VOLTS AT SEA LEVEL
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
  • Width Across Flats: 0.191 INCHES MAXIMUM IN
  • Unpackaged Unit Weight: 0.4 GRAMS NOMINAL G
  • Inclosure Type: ENCASED
  • Body Surface Treatment: TIN
  • Power Line Frequency Rating Per Function in Hertz: 424.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Identification
  • NSN: 5915-01-175-8326
  • NIIN: 011758326
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-175-8326, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 24 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-01-175-8326
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Maximum Dielectric Withstanding DC Voltage375.0 VOLTS AT SEA LEVEL
Mounting Facility Type and Quantity1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
Width Across Flats0.191 INCHES MAXIMUM IN
Unpackaged Unit Weight0.4 GRAMS NOMINAL G
Inclosure TypeENCASED
Body Surface TreatmentTIN
Power Line Frequency Rating Per Function in Hertz424.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Functional Terminal Type and Quantity1 PIN INPUT FIRST FUNCTION
Functional Terminal Type and Quantity1 PIN OUTPUT SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Vibration Resistance Range in Hertz+10.0 TO 2000.0
Style DesignatorROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Nominal Thread Size0.164 INCHES IN
Specification/standard Data81349-MIL-F-15733/44 GOVERNMENT SPECIFICATION
Body MaterialMETAL
Body Length0.305 INCHES MAXIMUM IN
Operating Voltage Rating and Type Per Function85.0 VOLTS AC BLANK AND 125.0 VOLTS DC BLANK LOCATION NOT OTHERWISE SPECIFIED
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
Operating Current Rating Per Function in Amps15.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Operating Temp Range-55.0 TO 125.0 CELSIUS DEGC
Test Data Document81349-MIL-F-15733 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Maximum Temp Rise75.0 CELSIUS DEGC
Load Impedance Per Function50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL D — Destroy Item
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-F-15733/44 5/9 Secondary reference
U.S. Government activity
M15733/44-0002 2/2 Government specification standardization
U.S. Government activity
MIL-PRF-15733/44 4/1 Identification reference
U.S. Government activity
10135218 6/9 Informative reference only
Nimikkeistokeskus Ncb Finland

Frequently Asked Questions

What is NSN 5915-01-175-8326?

NSN 5915-01-175-8326 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-01-175-8326?

Key specifications for 5915-01-175-8326: Maximum Dielectric Withstanding DC Voltage: 375.0 VOLTS AT SEA LEVEL; Mounting Facility Type and Quantity: 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED; Width Across Flats: 0.191 INCHES MAXIMUM IN; Unpackaged Unit Weight: 0.4 GRAMS NOMINAL G. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5915-01-175-8326 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5915-01-175-8326?

NSN 5915-01-175-8326 has DEMIL Code D. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.