PartsTable TECHNICAL DATA SHEET
NSN 5915-01-174-5432Government record, cited

Filter, Band Pass5915-01-174-5432

NSN 5915-01-174-5432 · NIIN 011745432 · Part number S5311
Mercury Systems Inc · FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components · CAGE 51719
Government record, cited
NSN 5915-01-174-5432 — this item is cataloged by the U.S. Government under National Stock Number 5915-01-174-5432. Manufacturer of record part number: S5311.
Also searched as  5915-01-174-5432 · 5915011745432 · NIIN 011745432 · 01-174-5432 · FSC 5915 Filters and Networks · CAGE 51719 · S5311
Nearby stock numbers  ·
Features
  • Filter,band Pass — FSC 5915
  • Reference Frequency Per Function: 3.2 GIGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
  • Voltage Standing Wave Ratio Per Function: 1.5 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: ENCASED
  • Source Impedance Rating Per Function: 50.0 OHMS SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
  • Body Width: 1.000 INCHES NOMINAL IN
  • Body Height: 3.350 INCHES NOMINAL IN
Identification
  • NSN: 5915-01-174-5432
  • NIIN: 011745432
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: S5311
  • Manufacturer: Mercury Systems Inc
General Description

The Filter,band Pass, cataloged under National Stock Number 5915-01-174-5432, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Mercury Systems Inc. Government technical data includes 12 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-01-174-5432
Primary Part NumberS5311
Item NameFilter,band Pass
FSC / FSG5915 / 59 — Filters and Networks
ManufacturerMercury Systems Inc
StatusACTIVE
Reference Frequency Per Function3.2 GIGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
Mounting Facility Type and Quantity4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Voltage Standing Wave Ratio Per Function1.5 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeENCASED
Source Impedance Rating Per Function50.0 OHMS SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
Body Width1.000 INCHES NOMINAL IN
Body Height3.350 INCHES NOMINAL IN
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Nominal Thread Size0.112 INCHES IN
Body Length3.000 INCHES NOMINAL IN
Frequency Band Width Per Function50.00 MEGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
Insertion Loss at Reference Frequency Per Function in Decibels0.5 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
S5311 PRIMARY Mercury Systems Inc (USA)

Frequently Asked Questions

What is NSN 5915-01-174-5432?

NSN 5915-01-174-5432 is a Filter,band Pass, manufactured by Mercury Systems Inc, classified under FSC 5915, Filters and Networks. Status: active.

What part numbers are listed for NSN 5915-01-174-5432?

NSN 5915-01-174-5432 has 1 manufacturer part number on file: S5311 (Mercury Systems Inc).

What are the specifications of S5311?

Key specifications for S5311: Reference Frequency Per Function: 3.2 GIGAHERTZ SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Voltage Standing Wave Ratio Per Function: 1.5 SINGLE BAND PASS LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: ENCASED. 12 specifications are documented in the U.S. Government catalog.

Is NSN 5915-01-174-5432 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.