The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-118-9203, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 8 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-118-9203 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | ENCASED |
| Functional Terminal Type and Quantity | 2 TAB, SOLDER LUG INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED |
| Style Designator | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Mounting Facility Screw Thread Series Designator | UNF |
| Nominal Thread Size | 0.250 INCHES IN |
| Body Length | 0.540 INCHES MAXIMUM IN |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC SINGLE RADIO INTERFERENCE AND 150.0 VOLTS DC SINGLE RADIO INTERFERENCE LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 71010029001 | 5/9 Secondary reference Teledyne Readco Sub of Teledyne Inc |
| 536499-36 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5915-01-118-9203 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-01-118-9203: Mounting Facility Type and Quantity: 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: ENCASED; Functional Terminal Type and Quantity: 2 TAB, SOLDER LUG INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED; Style Designator: ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES. 8 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.