The Filter,band Pass, cataloged under National Stock Number 5915-01-110-7981, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-110-7981 |
| Item Name | Filter,band Pass |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Reference Frequency Per Function | 7.1 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| Voltage Standing Wave Ratio Per Function | 1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | ENCASED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.250 INCHES NOMINAL IN |
| Functional Terminal Type and Quantity | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| Functional Terminal Type and Quantity | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| Body Width | 2.000 INCHES NOMINAL IN |
| Body Height | 4.750 INCHES NOMINAL IN |
| Mounting Facility Screw Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Material | METAL |
| Body Length | 2.000 INCHES NOMINAL IN |
| Voltage Standing Wave Ratio Frequency Limits Per Function | 6.82 GIGAHERTZ BLANK AND 7.38 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Input Impedance Per Function W/load | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Discrimination at Specified Frequencies Per Function in Decibels | 35.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.000 INCHES NOMINAL IN |
| Frequency Band Width Per Function | 6.82 GIGAHERTZ BLANK AND 7.38 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Insertion Loss at Reference Frequency Per Function in Decibels | 1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Output Impedance Per Function W/source Across Input | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Specified Frequencies of Discrimination Per Function | 6.62 GIGAHERTZ BLANK AND 6.82 GIGAHERTZ BLANK AND 7.38 GIGAHERTZ BLANK AND 7.58 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| A98-21404 | 3/9 Design control — primary reference Communications & Power Industries Dba Communications & Power Industries Div Solid State Products Division |
| 06T1-078-01 | 5/9 Secondary reference Racom Corp |
| K020440003 | 5/9 Secondary reference F E L Corp |
| A98-21404-001 | 5/9 Secondary reference Communications & Power Industries Dba Communications & Power Industries Div Solid State Products Division |
NSN 5915-01-110-7981 is a Filter,band Pass, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-01-110-7981: Reference Frequency Per Function: 7.1 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 5.500 INCHES NOMINAL IN; Voltage Standing Wave Ratio Per Function: 1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED. 21 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.