The Filter,low Pass, cataloged under National Stock Number 5915-01-100-5683, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 12 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-100-5683 |
| Item Name | Filter,low Pass |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Reference Frequency Per Function | 350.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | ENCASED |
| Functional Terminal Type and Quantity | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| Functional Terminal Type and Quantity | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| Body Outside Diameter | 0.500 INCHES NOMINAL IN |
| Source Impedance Rating Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Style Designator | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Body Material | METAL |
| Frequency Band Width Per Function | 100.00 MEGAHERTZ BLANK AND 700.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Temp Range | -55.0 TO 125.0 CELSIUS DEGC |
| Insertion Loss at Reference Frequency Per Function in Decibels | 1.4 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Load Impedance Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| FLT/2-700-7/50-3A/3B | 3/9 Design control — primary reference Trilithic, Inc. |
NSN 5915-01-100-5683 is a Filter,low Pass, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-01-100-5683: Reference Frequency Per Function: 350.0 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: ENCASED; Functional Terminal Type and Quantity: 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION; Functional Terminal Type and Quantity: 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION. 12 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.