The Filter,low Pass, cataloged under National Stock Number 5915-01-037-7816, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-037-7816 |
| Item Name | Filter,low Pass |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Reference Frequency Per Function | 2.1 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Mounting Facility Type and Quantity | 2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | HERMETICALLY SEALED |
| Body Surface Treatment | SILVER |
| Precious Material | SILVER |
| Output Terminal Identification | UG-1619/U |
| Functional Terminal Type and Quantity | 1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION |
| Functional Terminal Type and Quantity | 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION |
| Body Outside Diameter | 0.750 INCHES NOMINAL0.750 INCHES NOMINAL IN |
| Source Impedance Rating Per Function | 91.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Output Terminal Manufacturer Code | 80063 |
| Style Designator | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Body Material | METAL |
| Body Length | 3.500 INCHES NOMINAL3.500 INCHES NOMINAL IN |
| Input Terminal Manufacturer Code | 80063 |
| Discrimination at Specified Frequencies Per Function in Decibels | 3.0 MAXIMUM BLANK AND 34.0 MINIMUM BLANK AND 70.0 MINIMUM BLANK FIRST FUNCTION |
| Principal Circuitry Type Per Function | INDUCTANCE-CAPACITANCE-RESISTANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Precious Material and Location | TERMINALS SILVER |
| Frequency Band Width Per Function | 1.00 HERTZ BLANK AND 4.20 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Input Terminal Identification | UG-1094/U |
| Operating Temp Range | -35.0 TO 95.0 CELSIUS-35.0 TO 95.0 CELSIUS DEGC |
| Insertion Loss at Reference Frequency Per Function in Decibels | 3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Load Impedance Per Function | 91.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Specified Frequencies of Discrimination Per Function | 1.00 HERTZ BLANK AND 4.20 MEGAHERTZ BLANK AND 11.00 MEGAHERTZ BLANK AND 22.00 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Average Life Rating in Hours | 10000.010000.0 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL B — Remove Demilitarization Key Points |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| SC-B-730013-2 | 5/9 Secondary reference U.S. Government activity |
| SC-B-730013-2 | 5/9 Secondary reference Systems and Electronics Inc |
| SC-B-730013-2 | 3/2 Design control — primary reference U.S. Government activity |
| LPF103533-2 | 5/2 Secondary reference U.S. Government activity |
NSN 5915-01-037-7816 is a Filter,low Pass, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-01-037-7816: Reference Frequency Per Function: 2.1 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: HERMETICALLY SEALED; Body Surface Treatment: SILVER. 25 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
NSN 5915-01-037-7816 has DEMIL Code B. Demilitarization may be required before disposal or transfer to non-military entities.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.