The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-01-007-0544, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 14 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-01-007-0544 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | ENCASED |
| Power Line Frequency Rating Per Function in Hertz | 400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG INPUT SECOND FUNCTION |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| Body Outside Diameter | 0.415 INCHES MAXIMUM IN |
| Source Impedance Rating Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Style Designator | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Mounting Facility Screw Thread Series Designator | UNF |
| Nominal Thread Size | 0.250 INCHES IN |
| Body Length | 0.540 INCHES MAXIMUM IN |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Current Rating Per Function in Amps | 1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Load Impedance Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| CF252-2 | 3/9 Design control — primary reference U.S. Government activity |
NSN 5915-01-007-0544 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-01-007-0544: Mounting Facility Type and Quantity: 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: ENCASED; Power Line Frequency Rating Per Function in Hertz: 400.0 BLANK LOCATION NOT OTHERWISE SPECIFIED; Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG INPUT SECOND FUNCTION. 14 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.