The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-994-2554, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 10 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-00-994-2554 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Inclosure Type | ENCASED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.069 INCHES MINIMUM AND 2.031 INCHES MAXIMUM IN |
| Power Line Frequency Rating Per Function in Hertz | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Power Line Frequency Rating Per Function in Hertz | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Body Width | 1.031 INCHES MAXIMUM IN |
| Body Height | 2.906 INCHES MAXIMUM IN |
| Style Designator | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| Body Length | 2.531 INCHES MAXIMUM IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 2.140 INCHES MINIMUM AND 2.202 INCHES MAXIMUM IN |
| Operating Temp Range | -65.0 TO 85.0 CELSIUS DEGC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 30A14 | 3/9 Design control — primary reference L3 Technologies, Inc. Dba Insight Technology Division Div Insight Technology Division |
NSN 5915-00-994-2554 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-00-994-2554: Overall Height: 3.249 INCHES MAXIMUM IN; Inclosure Type: ENCASED; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 1.069 INCHES MINIMUM AND 2.031 INCHES MAXIMUM IN; Power Line Frequency Rating Per Function in Hertz: 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION. 10 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.