The Filter,band Pass, cataloged under National Stock Number 5915-00-976-1259, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 20 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-00-976-1259 |
| Item Name | Filter,band Pass |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Reference Frequency Per Function | 4.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| Inclosure Type | HERMETICALLY SEALED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.188 INCHES NOMINAL IN |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| Functional Terminal Type and Quantity | 1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| Body Width | 0.625 INCHES MAXIMUM IN |
| Body Height | 1.250 INCHES MAXIMUM IN |
| Style Designator | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| Mounting Facility Screw Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Nominal Thread Size | 0.112 INCHES IN |
| Body Material | METAL |
| Body Length | 1.250 INCHES MAXIMUM IN |
| Input Impedance Per Function W/load | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Discrimination at Specified Frequencies Per Function in Decibels | 35.0 MINIMUM BLANK AND 5.0 MAXIMUM BLANK FIRST FUNCTION |
| Frequency Band Width Per Function | 3.85 MEGAHERTZ BLANK AND 4.15 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Temp Range | -55.0 TO 80.0 CELSIUS DEGC |
| Insertion Loss at Reference Frequency Per Function in Decibels | 3.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Output Impedance Per Function W/source Across Input | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Specified Frequencies of Discrimination Per Function | 1.00 MEGAHERTZ BLANK AND 3.85 MEGAHERTZ BLANK AND 4.15 MEGAHERTZ BLANK AND 4.30 MEGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 673-0957-00 | 5/9 Secondary reference Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems |
| 673-0957-000 | 3/9 Design control — primary reference Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems |
NSN 5915-00-976-1259 is a Filter,band Pass, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-00-976-1259: Reference Frequency Per Function: 4.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: HERMETICALLY SEALED; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 1.188 INCHES NOMINAL IN. 20 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.