PartsTable TECHNICAL DATA SHEET
NSN 5915-00-907-5645Government record, cited

Filter, Band Pass5915-00-907-5645

NSN 5915-00-907-5645 · NIIN 009075645
FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5915-00-907-5645 · 5915009075645 · NIIN 009075645 · 00-907-5645 · FSC 5915 Filters and Networks
Nearby stock numbers  ·
Features
  • Filter,band Pass — FSC 5915
  • Reference Frequency Per Function: 2.465 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 5.000 INCHES NOMINAL IN
  • Functional Terminal Type and Quantity: 1 STANDARD TUBE BASE INPUT-OUTPUT/GROUND LOCATION NOT OTHERWISE SPECIFIED
  • Body Width: 1.563 INCHES NOMINAL IN
  • Body Height: 5.500 INCHES NOMINAL IN
Identification
  • NSN: 5915-00-907-5645
  • NIIN: 009075645
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,band Pass, cataloged under National Stock Number 5915-00-907-5645, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 17 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-907-5645
Item NameFilter,band Pass
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Reference Frequency Per Function2.465 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Mounting Facility Type and Quantity4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length5.000 INCHES NOMINAL IN
Functional Terminal Type and Quantity1 STANDARD TUBE BASE INPUT-OUTPUT/GROUND LOCATION NOT OTHERWISE SPECIFIED
Body Width1.563 INCHES NOMINAL IN
Body Height5.500 INCHES NOMINAL IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Nominal Thread Size0.138 INCHES IN
Body MaterialMETAL
Body Length2.062 INCHES NOMINAL IN
Input Impedance Per Function W/load600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.563 INCHES NOMINAL IN
Frequency Band Width Per Function2.4225 KILOHERTZ BLANK AND 2.5075 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Output Impedance Per Function W/source Across Input600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Specified Frequencies of Discrimination Per Function2.38 KILOHERTZ BLANK AND 2.42 KILOHERTZ BLANK AND 2.50 KILOHERTZ BLANK AND 2.55 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
A43000014-13 3/9 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-907-5645?

NSN 5915-00-907-5645 is a Filter,band Pass, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-00-907-5645?

Key specifications for 5915-00-907-5645: Reference Frequency Per Function: 2.465 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 5.750 INCHES NOMINAL IN; Inclosure Type: HERMETICALLY SEALED. 17 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-907-5645 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com