Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Source Impedance Rating Per Function: 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 620.0 3RD RADIO INTERFERENCE THIRD FUNCTION
  • Principal Circuitry Type Per Function: INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Maximum Voltage Drop Per Function: 300.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
  • Source Impedance Rating Per Function: 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 620.0 2ND RADIO INTERFERENCE SECOND FUNCTION
  • Body Height: 2.000 INCHES NOMINAL IN
Applications
  • Fluid filtration and purification
  • Engine intake air cleaning
  • Hydraulic system protection
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-901-9241, is classified within Federal Supply Class 5915 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Jednolity Indeks Materialowy - Uniform Material Index. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 9 commercial cross-references from 8 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-901-9241
Primary Part Number5915PL0803951
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — No Item Name Available
ManufacturerJednolity Indeks Materialowy - Uniform Material Index
StatusACTIVE
Source Impedance Rating Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Power Line Frequency Rating Per Function in Hertz620.0 3RD RADIO INTERFERENCE THIRD FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
Maximum Voltage Drop Per Function300.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Power Line Frequency Rating Per Function in Hertz620.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Body Height2.000 INCHES NOMINAL IN
Operating Current Rating Per Function in Amps15.0 3RD RADIO INTERFERENCE THIRD FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
Load Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Maximum Voltage Drop Per Function300.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Load Impedance Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Operating Voltage Rating and Type Per Function120.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Voltage Rating and Type Per Function120.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
Unpackaged Unit Weight4.000 POUNDS NOMINAL LBS
Body MaterialMETAL
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
Functional Terminal Type and Quantity3 THREADED STUD OUTPUT SECOND FUNCTION
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Functional Terminal Type and Quantity3 THREADED STUD INPUT FIRST FUNCTION
Body Length7.000 INCHES NOMINAL IN
Inclosure TypeENCASED
Maximum Voltage Drop Per Function300.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.750 INCHES NOMINAL IN
Power Line Frequency Rating Per Function in Hertz620.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Load Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length7.500 INCHES NOMINAL IN
Operating Current Rating Per Function in Amps15.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Body Width2.500 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 12
5915-00-009-1321JN10-2270A INTERCHANGEABLE
Filter,radio Frequency Interfere
Sprague Electric Co World Hqs
5915-00-058-2995JN17-1958A INTERCHANGEABLE
Filter,radio Frequency Interfere
Sprague Electric Co World Hqs
5915-00-206-0086JN17-323B INTERCHANGEABLE
Filter,radio Frequency Interfere
Ems Development Corporation Dba Ems Development Corp
5915-00-501-226294637-01 INTERCHANGEABLE
Filter,radio Frequency Interfere
Ge Aviation Systems Llc
5915-00-501-4120JX64B INTERCHANGEABLE
Filter,radio Frequency Interfere
Sprague Electric Co World Hqs
5915-00-548-1745JW33-1554A INTERCHANGEABLE
Filter,band Pass
Sprague Electric Co World Hqs
5915-00-552-0084290369-000 INTERCHANGEABLE
Filter,radio Frequency Interfere
Stromberg-Carlson Corp a Plessey Telecommunications Co
5915-00-815-741914S296A INTERCHANGEABLE
Filter,radio Frequency Interfere
Sprague Electric Co World Hqs
5915-00-837-1668 INTERCHANGEABLE
Filter,radio Frequency Interfere
5915-00-849-480699JX34A INTERCHANGEABLE
Filter,radio Frequency Interfere
Ems Development Corporation Dba Ems Development Corp
Cross-Reference Index
Part NumberManufacturer
5915PL0803951 Jednolity Indeks Materialowy - Uniform Material Index (POL)
713880-132 Raytheon Company Div Rmd Strategic (USA)
GF6846-1 Spectrum Control, Inc. Div Api Technologies - Eis/wesson (USA)
DMS 82010B Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings) (USA)
6B346 Meggitt (new Hampshire), Inc (USA)
GF6846 Genisco Filter Corp (USA)
GF6846-1 Genisco Filter Corp (USA)
JN10-1483A1 Sprague Electric Co World Hqs (USA)
6B346 Sora Power Inc. Dba Sora Power Inc (USA)
Related Parts
5915-00-009-1321INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
JN10-2270A
5915-00-058-2995INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
JN17-1958A
5915-00-206-0086INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
JN17-323B
5915-00-501-2262INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
94637-01
5915-00-501-4120INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
JX64B
5915-00-548-1745INTERCHANGEABLE
FILTER,BAND PASS
JW33-1554A
5915-00-552-0084INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
290369-000
5915-00-815-7419INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
14S296A
5915-00-837-1668INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
5915-00-849-4806INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
99JX34A
5915-00-879-0458INTERCHANGEABLE
FILTER,LOW PASS
SMB524204-1
5915-00-910-6427INTERCHANGEABLE
FILTER,RADIO FREQUENCY INTERFERE
JN17-1518

Frequently Asked Questions

What is NSN 5915-00-901-9241?

NSN 5915-00-901-9241 is a Filter,radio Frequency Interfere, manufactured by Jednolity Indeks Materialowy - Uniform Material Index, classified under FSC 5915 (No Item Name Available). Status: active.

What are the part numbers for NSN 5915-00-901-9241?

NSN 5915-00-901-9241 has 9 cross-referenced part numbers: 5915PL0803951 (Jednolity Indeks Materialowy - Uniform Material Index), 713880-132 (Raytheon Company Div Rmd Strategic), GF6846-1 (Spectrum Control, Inc. Div Api Technologies - Eis/wesson), DMS 82010B (Dla Land and Maritime Dba Engineering and Technical Support Div Document Standardization Division (vendor Item Drawings)), 6B346 (Meggitt (new Hampshire), Inc) and 4 more.

What NSN replaces 5915-00-901-9241?

There are 12 known substitutes for 5915-00-901-9241: 5915-00-009-1321, 5915-00-058-2995, 5915-00-206-0086 and 9 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 5915PL0803951?

Key specifications for 5915PL0803951: Source Impedance Rating Per Function: 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION; Power Line Frequency Rating Per Function in Hertz: 620.0 3RD RADIO INTERFERENCE THIRD FUNCTION; Principal Circuitry Type Per Function: INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION; Maximum Voltage Drop Per Function: 300.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION. 30 total characteristics are documented in the Federal Logistics Information System.