Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Mounting Facility Type and Quantity: 12 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.985 INCHES MINIMUM AND 3.015 INCHES MAXIMUM IN
  • Power Line Frequency Rating Per Function in Hertz: 400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Identification
  • NSN: 5915-00-836-6552
  • NIIN: 008366552
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-836-6552, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-836-6552
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Mounting Facility Type and Quantity12 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.985 INCHES MINIMUM AND 3.015 INCHES MAXIMUM IN
Power Line Frequency Rating Per Function in Hertz400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Functional Terminal Type and Quantity4 THREADED STUD OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity1 THREADED STUD GROUND THIRD FUNCTION
Functional Terminal Type and Quantity1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
Source Impedance Rating Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Vibration Resistance Range in Hertz+10.0 TO 55.0
Body Width2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM IN
Body Height4.970 INCHES MINIMUM AND 5.030 INCHES MAXIMUM IN
Maximum Voltage Drop Per Function250.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Maximum Voltage Drop Per Function250.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Maximum Voltage Drop Per Function250.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
Maximum Voltage Drop Per Function250.0 MILLIVOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
Mounting Facility Screw Thread Series DesignatorUNF
Maximum Dielectric Withstanding AC Rms Voltage312.5 VOLTS AT SEA LEVEL
Nominal Thread Size0.190 INCHES IN
Body MaterialMETAL
Body Length3.970 INCHES MINIMUM AND 4.030 INCHES MAXIMUM IN
Operating Voltage Rating and Type Per Function125.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Voltage Rating and Type Per Function125.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
3130-01-230-098340105-5 POSSIBLE MATCH
HOUSING,BEARING UNIT
Possible match (shared part number)Meggitt Defense Systems, Inc. Dba Meggitt Defense Systems Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
401055 7/9 Vendor item drawing reference
Ail Systems Inc Sub of Eaton Corp
GF-3506-1 3/9 Design control — primary reference
Spectrum Control, Inc. Div Api Technologies - Eis/wesson
GF-3506-1 5/9 Secondary reference
Genisco Filter Corp
Related Parts
3130-01-230-0983POSSIBLE MATCH
HOUSING,BEARING UNIT
40105-5

Frequently Asked Questions

What is NSN 5915-00-836-6552?

NSN 5915-00-836-6552 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.

What NSN replaces 5915-00-836-6552?

1 possible match (shared part number, not a government interchangeability claim): 3130-01-230-0983. Verify interchangeability with system specifications before substitution.

What are the specifications of 5915-00-836-6552?

Key specifications for 5915-00-836-6552: Mounting Facility Type and Quantity: 12 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 6.906 INCHES NOMINAL IN; Inclosure Type: HERMETICALLY SEALED; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.985 INCHES MINIMUM AND 3.015 INCHES MAXIMUM IN. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-836-6552 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com