The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-816-4272, is classified within Federal Supply Class 5915 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Raytheon Company. Government technical data includes 26 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 4 manufacturers, enabling identification through both NSN and commercial part number lookups. 7 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-00-816-4272 |
| Primary Part Number | 327867-1 |
| Item Name | Filter,radio Frequency Interfere |
| FSC / FSG | 5915 / 59 — No Item Name Available |
| Manufacturer | Raytheon Company |
| Status | ACTIVE |
| Source Impedance Rating Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Power Line Frequency Rating Per Function in Hertz | 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| Functional Terminal Type and Quantity | 3 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| Load Impedance Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Body Length | 5.312 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 4.356 INCHES NOMINAL IN |
| Functional Terminal Type and Quantity | 3 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| Inclosure Type | ENCASED |
| Body Width | 4.813 INCHES NOMINAL IN |
| Load Impedance Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| Load Impedance Per Function | 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Operating Voltage Rating and Type Per Function | 125.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Mounting Facility Type and Quantity | 6 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| Unthreaded Mounting Hole Diameter | 0.188 INCHES NOMINAL IN |
| Operating Current Rating Per Function in Amps | 0.009 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 4.813 INCHES NOMINAL IN |
| Power Line Frequency Rating Per Function in Hertz | 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Source Impedance Rating Per Function | 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Operating Current Rating Per Function in Amps | 0.009 2ND RADIO INTERFERENCE SECOND FUNCTION |
| Power Line Frequency Rating Per Function in Hertz | 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| Source Impedance Rating Per Function | 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| Operating Temp Range | -55.0 TO 85.0 CELSIUS DEGC |
| Style Designator | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| Operating Current Rating Per Function in Amps | 0.009 3RD RADIO INTERFERENCE THIRD FUNCTION |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
NSN 5915-00-816-4272 is a Filter,radio Frequency Interfere, manufactured by Raytheon Company, classified under FSC 5915 (No Item Name Available). Status: active.
NSN 5915-00-816-4272 has 4 cross-referenced part numbers: FA9660 (Ems Development Corporation Dba Ems Development Corp), 327867-1 (Raytheon Company), 378-1 (American Trans-Coil Corp), FA9660 (Filtron Co Inc Div of Rfi Corp).
There are 7 known substitutes for 5915-00-816-4272: 5330-00-154-6210, 3110-00-227-4058, 4320-00-398-6369 and 4 more. Verify interchangeability with system specifications before substitution.
Key specifications for 327867-1: Overall Height: 1.469 INCHES NOMINAL IN; Source Impedance Rating Per Function: 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION; Power Line Frequency Rating Per Function in Hertz: 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION; Functional Terminal Type and Quantity: 3 TAB, SOLDER LUG INPUT FIRST FUNCTION. 29 total characteristics are documented in the Federal Logistics Information System.