PartsTable TECHNICAL DATA SHEET
NSN 5915-00-804-5805Government record, cited

Filter, Radio Frequency Interfere5915-00-804-5805

NSN 5915-00-804-5805 · NIIN 008045805
FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5915-00-804-5805 · 5915008045805 · NIIN 008045805 · 00-804-5805 · FSC 5915 Filters and Networks · 558-1611-002 · SA8045-805 · SM-B-344936
Nearby stock numbers  ·
Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Mounting Facility Type and Quantity: 1 CLAMP LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: ENCASED
  • Functional Terminal Type and Quantity: 1 WIRE LOOP OUTPUT SECOND FUNCTION
  • Functional Terminal Type and Quantity: 1 WIRE LOOP INPUT FIRST FUNCTION
  • Body Outside Diameter: 0.281 INCHES NOMINAL IN
  • Source Impedance Rating Per Function: 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
  • Maximum Voltage Drop Per Function: 800.0 MILLIVOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
Identification
  • NSN: 5915-00-804-5805
  • NIIN: 008045805
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-804-5805, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 13 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-804-5805
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Mounting Facility Type and Quantity1 CLAMP LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeENCASED
Functional Terminal Type and Quantity1 WIRE LOOP OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity1 WIRE LOOP INPUT FIRST FUNCTION
Body Outside Diameter0.281 INCHES NOMINAL IN
Source Impedance Rating Per Function50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Maximum Voltage Drop Per Function800.0 MILLIVOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
Style DesignatorROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
Body MaterialMETAL
Operating Voltage Rating and Type Per Function8.26 VOLTS AC BLANK LOCATION NOT OTHERWISE SPECIFIED
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED
Operating Current Rating Per Function in Amps0.58 BLANK LOCATION NOT OTHERWISE SPECIFIED
Load Impedance Per Function50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
558-1611-002 5/9 Secondary reference
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
SA8045-805 5/9 Secondary reference
Aschbacher & Associates Inc
SM-B-344936 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-804-5805?

NSN 5915-00-804-5805 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-00-804-5805?

Key specifications for 5915-00-804-5805: Mounting Facility Type and Quantity: 1 CLAMP LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: ENCASED; Functional Terminal Type and Quantity: 1 WIRE LOOP OUTPUT SECOND FUNCTION; Functional Terminal Type and Quantity: 1 WIRE LOOP INPUT FIRST FUNCTION. 13 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-804-5805 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com