PartsTable TECHNICAL DATA SHEET
NSN 5915-00-722-7928Government record, cited

Filter, Band Pass5915-00-722-7928

NSN 5915-00-722-7928 · NIIN 007227928 · Part number 132694
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp · FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components · CAGE 06481
Government record, cited
NSN 5915-00-722-7928 — this item is cataloged by the U.S. Government under National Stock Number 5915-00-722-7928. Manufacturer of record part number: 132694.
Also searched as  5915-00-722-7928 · 5915007227928 · NIIN 007227928 · 00-722-7928 · FSC 5915 Filters and Networks · CAGE 06481 · 132694 · TBA-1060-100-4EF1 · F943APX7
Nearby stock numbers  ·
Features
  • Filter,band Pass — FSC 5915
  • Reference Frequency Per Function: 1.02 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION
  • Reference Frequency Per Function: 1.10 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION
  • Mounting Facility Type and Quantity: 2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
  • Voltage Standing Wave Ratio Per Function: 1.5 2ND BAND PASS SECOND FUNCTION
  • Voltage Standing Wave Ratio Per Function: 1.5 1ST BAND PASS FIRST FUNCTION
  • Inclosure Type: ENCASED
  • Average Power Rating Per Function: 15.0 WATTS 1ST BAND PASS FIRST FUNCTION
Identification
  • NSN: 5915-00-722-7928
  • NIIN: 007227928
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 132694
  • Manufacturer: Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
General Description

The Filter,band Pass, cataloged under National Stock Number 5915-00-722-7928, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp. Government technical data includes 28 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-722-7928
Primary Part Number132694
Item NameFilter,band Pass
FSC / FSG5915 / 59 — Filters and Networks
ManufacturerNorthrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp
StatusACTIVE
Reference Frequency Per Function1.02 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION
Reference Frequency Per Function1.10 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION
Mounting Facility Type and Quantity2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED
Voltage Standing Wave Ratio Per Function1.5 2ND BAND PASS SECOND FUNCTION
Voltage Standing Wave Ratio Per Function1.5 1ST BAND PASS FIRST FUNCTION
Inclosure TypeENCASED
Average Power Rating Per Function15.0 WATTS 1ST BAND PASS FIRST FUNCTION
Average Power Rating Per Function15.0 WATTS 2ND BAND PASS SECOND FUNCTION
Functional Terminal Type and Quantity1 CONNECTOR, RECEPTACLE OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity1 CONNECTOR, PLUG INPUT FIRST FUNCTION
Body Outside Diameter0.750 INCHES NOMINAL IN
Vibration Resistance Range in Hertz+5.0 TO 500.0
Style DesignatorROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES
Voltage Standing Wave Ratio Frequency Limits Per Function1.01 GIGAHERTZ 1ST BAND PASS AND 1.03 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION
Voltage Standing Wave Ratio Frequency Limits Per Function1.09 GIGAHERTZ 2ND BAND PASS AND 1.11 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION
Input Impedance Per Function W/load50.0 OHMS 2ND BAND PASS SECOND FUNCTION
Input Impedance Per Function W/load50.0 OHMS 1ST BAND PASS FIRST FUNCTION
Discrimination at Specified Frequencies Per Function in Decibels40.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION
Discrimination at Specified Frequencies Per Function in Decibels40.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION
Frequency Band Width Per Function1.01 GIGAHERTZ 1ST BAND PASS AND 1.03 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION
Frequency Band Width Per Function1.09 GIGAHERTZ 2ND BAND PASS AND 1.11 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION
Operating Temp Range-54.0 TO 71.0 CELSIUS DEGC
Insertion Loss at Reference Frequency Per Function in Decibels0.5 1ST BAND PASS FIRST FUNCTION
Insertion Loss at Reference Frequency Per Function in Decibels0.5 2ND BAND PASS SECOND FUNCTION
Output Impedance Per Function W/source Across Input50.0 OHMS 2ND BAND PASS SECOND FUNCTION
Output Impedance Per Function W/source Across Input50.0 OHMS 1ST BAND PASS FIRST FUNCTION
Specified Frequencies of Discrimination Per Function340.00 MEGAHERTZ 1ST BAND PASS AND 1.01 GIGAHERTZ 1ST BAND PASS AND 1.03 GIGAHERTZ 1ST BAND PASS AND 2.00 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION
Specified Frequencies of Discrimination Per Function340.00 MEGAHERTZ 2ND BAND PASS AND 1.09 GIGAHERTZ 2ND BAND PASS AND 1.11 GIGAHERTZ 2ND BAND PASS AND 2.00 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
132694 Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA)
TBA-1060-100-4EF1 Telonic Berkeley, Inc. Dba Telonic Berkeley (USA)
Reference documents
ReferenceMeaning
F943APX7 3/2 Design control — primary reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5915-00-722-7928?

NSN 5915-00-722-7928 is a Filter,band Pass, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp, classified under FSC 5915, Filters and Networks. Status: active.

What part numbers are listed for NSN 5915-00-722-7928?

NSN 5915-00-722-7928 has 2 manufacturer part numbers on file: 132694 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp), TBA-1060-100-4EF1 (Telonic Berkeley, Inc. Dba Telonic Berkeley).

What are the specifications of 132694?

Key specifications for 132694: Reference Frequency Per Function: 1.02 GIGAHERTZ 1ST BAND PASS FIRST FUNCTION; Reference Frequency Per Function: 1.10 GIGAHERTZ 2ND BAND PASS SECOND FUNCTION; Mounting Facility Type and Quantity: 2 TERMINAL LOCATION NOT OTHERWISE SPECIFIED; Voltage Standing Wave Ratio Per Function: 1.5 2ND BAND PASS SECOND FUNCTION. 28 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-722-7928 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com