PartsTable TECHNICAL DATA SHEET
NSN 5915-00-644-5609Government record, cited

Filter, Band Pass5915-00-644-5609

NSN 5915-00-644-5609 · NIIN 006445609
FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5915-00-644-5609 · 5915006445609 · NIIN 006445609 · 00-644-5609 · FSC 5915 Filters and Networks · FX139ISSUEAPT2805 · FX139-2805 · 00606296011760
Nearby stock numbers  ·
Features
  • Filter,band Pass — FSC 5915
  • Reference Frequency Per Function: 2.805 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.125 INCHES NOMINAL IN
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG INPUT FIRST FUNCTION
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG GROUND THIRD FUNCTION
Identification
  • NSN: 5915-00-644-5609
  • NIIN: 006445609
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,band Pass, cataloged under National Stock Number 5915-00-644-5609, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 21 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-644-5609
Item NameFilter,band Pass
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Reference Frequency Per Function2.805 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Mounting Facility Type and Quantity4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.125 INCHES NOMINAL IN
Functional Terminal Type and Quantity1 TAB, SOLDER LUG INPUT FIRST FUNCTION
Functional Terminal Type and Quantity1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity1 TAB, SOLDER LUG GROUND THIRD FUNCTION
Body Width2.375 INCHES NOMINAL IN
Body Height3.812 INCHES NOMINAL IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Nominal Thread Size0.138 INCHES IN
Body MaterialMETAL
Body Length2.750 INCHES NOMINAL IN
Input Impedance Per Function W/load600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Discrimination at Specified Frequencies Per Function in Decibels20.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.750 INCHES NOMINAL IN
Frequency Band Width Per Function2.755 KILOHERTZ BLANK AND 2.855 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Insertion Loss at Reference Frequency Per Function in Decibels5.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Output Impedance Per Function W/source Across Input600.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Specified Frequencies of Discrimination Per Function2.645 KILOHERTZ BLANK AND 2.755 KILOHERTZ BLANK AND 2.855 KILOHERTZ BLANK AND 2.965 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
FX139ISSUEAPT2805 5/9 Secondary reference
U.S. Government activity
FX139-2805 3/9 Design control — primary reference
U.S. Government activity
00606296011760 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-644-5609?

NSN 5915-00-644-5609 is a Filter,band Pass, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-00-644-5609?

Key specifications for 5915-00-644-5609: Reference Frequency Per Function: 2.805 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 4.187 INCHES NOMINAL IN; Inclosure Type: HERMETICALLY SEALED. 21 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-644-5609 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com