PartsTable TECHNICAL DATA SHEET
NSN 5915-00-501-4155Government record, cited

Filter, Band Pass5915-00-501-4155

NSN 5915-00-501-4155 · NIIN 005014155 · Part number SC-C-63429
Aeroflex Laboratories Inc Comstron Div · FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components · CAGE 54832
Government record, cited
NSN 5915-00-501-4155 — this item is cataloged by the U.S. Government under National Stock Number 5915-00-501-4155. Manufacturer of record part number: SC-C-63429.
Also searched as  5915-00-501-4155 · 5915005014155 · NIIN 005014155 · 00-501-4155 · FSC 5915 Filters and Networks · CAGE 54832 · SC-C-63429 · ERLC1063 · GA51583
Nearby stock numbers  ·
Features
  • Filter,band Pass — FSC 5915
  • Reference Frequency Per Function: 120.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
  • Mounting Facility Type and Quantity: 2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 4.188 INCHES NOMINAL IN
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG INPUT FIRST FUNCTION
  • Functional Terminal Type and Quantity: 2 TAB, SOLDER LUG GROUND THIRD FUNCTION
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Identification
  • NSN: 5915-00-501-4155
  • NIIN: 005014155
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: SC-C-63429
  • Manufacturer: Aeroflex Laboratories Inc Comstron Div
General Description

The Filter,band Pass, cataloged under National Stock Number 5915-00-501-4155, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Aeroflex Laboratories Inc Comstron Div. Government technical data includes 24 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-501-4155
Primary Part NumberSC-C-63429
Item NameFilter,band Pass
FSC / FSG5915 / 59 — Filters and Networks
ManufacturerAeroflex Laboratories Inc Comstron Div
StatusACTIVE
Reference Frequency Per Function120.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Mounting Facility Type and Quantity2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length4.188 INCHES NOMINAL IN
Functional Terminal Type and Quantity1 TAB, SOLDER LUG INPUT FIRST FUNCTION
Functional Terminal Type and Quantity2 TAB, SOLDER LUG GROUND THIRD FUNCTION
Functional Terminal Type and Quantity1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Vibration Resistance Range in Hertz+10.0 TO 55.0
Body Width1.812 INCHES NOMINAL IN
Body Height2.531 INCHES NOMINAL IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Mounting Facility Screw Thread Series DesignatorUNF
Maximum Dielectric Withstanding AC Rms Voltage500.0 VOLTS AT SEA LEVEL
Nominal Thread Size0.190 INCHES IN
Body MaterialMETAL
Body Length4.844 INCHES NOMINAL IN
Input Impedance Per Function W/load130.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Discrimination at Specified Frequencies Per Function in Decibels65.0 MINIMUM BLANK AND 40.0 MINIMUM BLANK FIRST FUNCTION
Frequency Band Width Per Function116.00 KILOHERTZ BLANK AND 124.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Operating Temp Range-65.0 TO 185.0 FAHRENHEIT DEGF
Insertion Loss at Reference Frequency Per Function in Decibels4.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Output Impedance Per Function W/source Across Input40.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Specified Frequencies of Discrimination Per Function112.00 KILOHERTZ BLANK AND 116.00 KILOHERTZ BLANK AND 124.00 KILOHERTZ BLANK AND 128.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Average Life Rating in Hours10000.0
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL Q — CCL Item — Commerce Control List
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
SC-C-63429 Aeroflex Laboratories Inc Comstron Div (USA)
Reference documents
ReferenceMeaning
ERLC1063 5/9 Secondary reference
Electronic Research Company
GA51583 5/9 Secondary reference
American Telephone and Telegraph Co
SC-C-63429 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-501-4155?

NSN 5915-00-501-4155 is a Filter,band Pass, manufactured by Aeroflex Laboratories Inc Comstron Div, classified under FSC 5915, Filters and Networks. Status: active.

What part numbers are listed for NSN 5915-00-501-4155?

NSN 5915-00-501-4155 has 1 manufacturer part number on file: SC-C-63429 (Aeroflex Laboratories Inc Comstron Div).

What are the specifications of SC-C-63429?

Key specifications for SC-C-63429: Reference Frequency Per Function: 120.0 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 3.062 INCHES NOMINAL IN; Inclosure Type: HERMETICALLY SEALED. 24 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-501-4155 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

What is the DEMIL code for NSN 5915-00-501-4155?

NSN 5915-00-501-4155 has DEMIL Code Q. Demilitarization may be required before disposal or transfer to non-military entities.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com