The Filter,band Pass, cataloged under National Stock Number 5915-00-495-4665, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 6 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5915-00-495-4665 |
| Item Name | Filter,band Pass |
| FSC / FSG | 5915 / 59 — Filters and Networks |
| Status | ACTIVE |
| Reference Frequency Per Function | 1.03 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Functional Terminal Type and Quantity | 1 PIN OUTPUT SECOND FUNCTION |
| Source Impedance Rating Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Operating Temp Range | -55.0 TO 85.0 CELSIUS DEGC |
| Insertion Loss at Reference Frequency Per Function in Decibels | 2.5 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Load Impedance Per Function | 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 17009602 | 7/2 Vendor item drawing reference U.S. Government activity |
| BD-106 | 5/9 Secondary reference Trilithic, Inc. |
| SK1146 | 3/9 Design control — primary reference Teledyne Wireless, Llc Dba Teledyne Microwave Solutions |
| HQ1030-X15-2AA | 5/9 Secondary reference Teledyne Wireless, Llc Dba Teledyne Microwave Solutions |
NSN 5915-00-495-4665 is a Filter,band Pass, classified under FSC 5915, Filters and Networks. Status: active.
Key specifications for 5915-00-495-4665: Reference Frequency Per Function: 1.03 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Functional Terminal Type and Quantity: 1 PIN OUTPUT SECOND FUNCTION; Source Impedance Rating Per Function: 50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED; Operating Temp Range: -55.0 TO 85.0 CELSIUS DEGC. 6 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.