PartsTable TECHNICAL DATA SHEET
NSN 5915-00-170-3077Government record, cited

Filter, Radio Frequency Interfere5915-00-170-3077

NSN 5915-00-170-3077 · NIIN 001703077
FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5915-00-170-3077 · 5915001703077 · NIIN 001703077 · 00-170-3077 · FSC 5915 Filters and Networks · 32-810967-1 · SF1000 · JN10-2278A
Nearby stock numbers  ·
Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
  • Unpackaged Unit Weight: 6.000 POUNDS NOMINAL LBS
  • Inclosure Type: ENCASED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 5.220 INCHES NOMINAL IN
  • Power Line Frequency Rating Per Function in Hertz: 60.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
  • Functional Terminal Type and Quantity: 3 TAB, SOLDER LUG INPUT FIRST FUNCTION
  • Functional Terminal Type and Quantity: 3 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Identification
  • NSN: 5915-00-170-3077
  • NIIN: 001703077
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-170-3077, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-170-3077
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Unpackaged Unit Weight6.000 POUNDS NOMINAL LBS
Inclosure TypeENCASED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length5.220 INCHES NOMINAL IN
Power Line Frequency Rating Per Function in Hertz60.0 BLANK LOCATION NOT OTHERWISE SPECIFIED
Functional Terminal Type and Quantity3 TAB, SOLDER LUG INPUT FIRST FUNCTION
Functional Terminal Type and Quantity3 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Body Width3.840 INCHES NOMINAL IN
Body Height3.840 INCHES NOMINAL IN
Unthreaded Mounting Hole Diameter0.203 INCHES NOMINAL IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
Body MaterialMETAL
Body Length4.720 INCHES NOMINAL IN
Operating Voltage Rating and Type Per Function230.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Voltage Rating and Type Per Function230.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Voltage Rating and Type Per Function230.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Width3.090 INCHES NOMINAL IN
Operating Current Rating Per Function in Amps5.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Current Rating Per Function in Amps5.0 3RD RADIO INTERFERENCE THIRD FUNCTION
Operating Current Rating Per Function in Amps5.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Load Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Load Impedance Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Load Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
32-810967-1 3/9 Design control — primary reference
General Dynamics Advanced Information Systems Inc. Dba General Dynamics Advanced Information Systems
SF1000 5/9 Secondary reference
Crydom Corp
JN10-2278A 5/1 Secondary reference
Sprague Electric Co World Hqs
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-170-3077?

NSN 5915-00-170-3077 is a Filter,radio Frequency Interfere, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-00-170-3077?

Key specifications for 5915-00-170-3077: Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Unpackaged Unit Weight: 6.000 POUNDS NOMINAL LBS; Inclosure Type: ENCASED; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 5.220 INCHES NOMINAL IN. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-170-3077 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com