NSN 5915-00-166-8166 — this item is cataloged by the U.S. Government under National Stock Number 5915-00-166-8166. Primary manufacturer part number: 63-010.
Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Source Impedance Rating Per Function: 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
  • Operating Current Rating Per Function in Amps: 1.5 4TH RADIO INTERFERENCE FOURTH FUNCTION
  • Operating Current Rating Per Function in Amps: 2.5 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Operating Current Rating Per Function in Amps: 1.0 2ND RADIO INTERFERENCE SECOND FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Operating Current Rating Per Function in Amps: 1.5 3RD RADIO INTERFERENCE THIRD FUNCTION
  • Source Impedance Rating Per Function: 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Applications
  • Fluid filtration and purification
  • Engine intake air cleaning
  • Hydraulic system protection
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-166-8166, is classified within Federal Supply Class 5915 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Polara Engineering, Inc.. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 5 commercial cross-references from 5 manufacturers, enabling identification through both NSN and commercial part number lookups. 5 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-166-8166
Primary Part Number63-010
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — No Item Name Available
ManufacturerPolara Engineering, Inc.
StatusACTIVE
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Current Rating Per Function in Amps1.5 4TH RADIO INTERFERENCE FOURTH FUNCTION
Operating Current Rating Per Function in Amps2.5 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Current Rating Per Function in Amps1.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Current Rating Per Function in Amps1.5 3RD RADIO INTERFERENCE THIRD FUNCTION
Source Impedance Rating Per Function50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
Maximum Voltage Drop Per Function750.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Load Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Maximum Voltage Drop Per Function750.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
Maximum Voltage Drop Per Function400.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Inclosure TypeENCASED
Operating Voltage Rating and Type Per Function28.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
Functional Terminal Type and Quantity4 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Operating Voltage Rating and Type Per Function26.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
Functional Terminal Type and Quantity5 TAB, SOLDER LUG INPUT FIRST FUNCTION
Nominal Thread Size0.138 INCHES IN
Mounting Facility Type and Quantity2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Load Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length5.820 INCHES MINIMUM AND 5.840 INCHES MAXIMUM IN
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Maximum Voltage Drop Per Function750.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
Maximum Dielectric Withstanding DC Voltage322.0 VOLTS AT SEA LEVEL
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 5
5120-00-030-7933 INTERCHANGEABLE
Step Plate,mechanical Puller
2910-00-294-0327 INTERCHANGEABLE
Carburetor,float
4730-01-398-4530630-10 INTERCHANGEABLE
Clamp,hose
Acd Tridon Inc
8120-01-651-647063010 INTERCHANGEABLE
Cylinder,compressed Gas
Mastercool Inc
5340-01-697-350663010 INTERCHANGEABLE
Clamp,loop
Rohr, Inc. Dba Rohr Industries Inc Div Rohr Inc., a Part of Collins Aerospace
Cross-Reference Index
Part NumberManufacturer
63-010 PRIMARY Polara Engineering, Inc. (USA)
LMF1288 Lindgren Rf Enclosures Inc Lectromagnetics Div (USA)
8833300002-1 Navcom Defense Electronics, Inc. (USA)
RF9287 Ems Development Corporation Dba Ems Development Corp (USA)
573A94 Cardwell Condenser Corp Lapointe-Admiral Div (USA)
Related Parts
5120-00-030-7933INTERCHANGEABLE
STEP PLATE,MECHANICAL PULLER
2910-00-294-0327INTERCHANGEABLE
CARBURETOR,FLOAT
4730-01-398-4530INTERCHANGEABLE
CLAMP,HOSE
630-10
8120-01-651-6470INTERCHANGEABLE
CYLINDER,COMPRESSED GAS
63010
5340-01-697-3506INTERCHANGEABLE
CLAMP,LOOP
63010

Frequently Asked Questions

What is NSN 5915-00-166-8166?

NSN 5915-00-166-8166 is a Filter,radio Frequency Interfere, manufactured by Polara Engineering, Inc., classified under FSC 5915 (No Item Name Available). Status: active.

What are the part numbers for NSN 5915-00-166-8166?

NSN 5915-00-166-8166 has 5 cross-referenced part numbers: 63-010 (Polara Engineering, Inc.), LMF1288 (Lindgren Rf Enclosures Inc Lectromagnetics Div), 8833300002-1 (Navcom Defense Electronics, Inc.), RF9287 (Ems Development Corporation Dba Ems Development Corp), 573A94 (Cardwell Condenser Corp Lapointe-Admiral Div).

What NSN replaces 5915-00-166-8166?

There are 5 known substitutes for 5915-00-166-8166: 5120-00-030-7933, 2910-00-294-0327, 4730-01-398-4530 and 2 more. Verify interchangeability with system specifications before substitution.

What are the specifications of 63-010?

Key specifications for 63-010: Source Impedance Rating Per Function: 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION; Operating Current Rating Per Function in Amps: 1.5 4TH RADIO INTERFERENCE FOURTH FUNCTION; Operating Current Rating Per Function in Amps: 2.5 1ST RADIO INTERFERENCE FIRST FUNCTION; Operating Current Rating Per Function in Amps: 1.0 2ND RADIO INTERFERENCE SECOND FUNCTION. 30 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com