PartsTable TECHNICAL DATA SHEET
NSN 5915-00-057-5804Government record, cited

Filter, Band Pass5915-00-057-5804

NSN 5915-00-057-5804 · NIIN 000575804
FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5915-00-057-5804 · 5915000575804 · NIIN 000575804 · 00-057-5804 · FSC 5915 Filters and Networks · 526-7770-010 · 2515586
Nearby stock numbers  ·
Features
  • Filter,band Pass — FSC 5915
  • Maximum Dielectric Withstanding DC Voltage: 100.0 VOLTS AT SEA LEVEL
  • Reference Frequency Per Function: 147.5 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
  • Mounting Facility Type and Quantity: 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 0.959 INCHES MINIMUM AND 0.991 INCHES MAXIMUM IN
  • Functional Terminal Type and Quantity: 1 TAB, SOLDER LUG INPUT FIRST FUNCTION
  • Functional Terminal Type and Quantity: 2 TAB, SOLDER LUG GROUND THIRD FUNCTION
Identification
  • NSN: 5915-00-057-5804
  • NIIN: 000575804
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Filter,band Pass, cataloged under National Stock Number 5915-00-057-5804, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-057-5804
Item NameFilter,band Pass
FSC / FSG5915 / 59 — Filters and Networks
StatusACTIVE
Maximum Dielectric Withstanding DC Voltage100.0 VOLTS AT SEA LEVEL
Reference Frequency Per Function147.5 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Mounting Facility Type and Quantity4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length0.959 INCHES MINIMUM AND 0.991 INCHES MAXIMUM IN
Functional Terminal Type and Quantity1 TAB, SOLDER LUG INPUT FIRST FUNCTION
Functional Terminal Type and Quantity2 TAB, SOLDER LUG GROUND THIRD FUNCTION
Functional Terminal Type and Quantity1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Source Impedance Rating Per Function1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Body Width1.010 INCHES MAXIMUM IN
Body Height1.500 INCHES MAXIMUM IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Nominal Thread Size0.112 INCHES IN
Body Length1.920 INCHES MAXIMUM IN
Discrimination at Specified Frequencies Per Function in Decibels30.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION
Distance Between Centerlines of Mounting Facilities Parallel to Body Width0.440 INCHES MINIMUM AND 0.560 INCHES MAXIMUM IN
Frequency Band Width Per Function147.20 KILOHERTZ BLANK AND 147.80 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Operating Temp Range+0.0 TO 75.0 CELSIUS DEGC
Insertion Loss at Reference Frequency Per Function in Decibels3.5 BLANK LOCATION NOT OTHERWISE SPECIFIED
Test Data Document10001-2515586 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
Load Impedance Per Function1.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED
Specified Frequencies of Discrimination Per Function143.00 KILOHERTZ BLANK AND 147.20 KILOHERTZ BLANK AND 147.80 KILOHERTZ BLANK AND 152.00 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
526-7770-010 3/2 Design control — primary reference
U.S. Government activity
2515586 7/2 Vendor item drawing reference
Navair and Navsea Managed Original Design Activity Dwg Not Material/parts Supplier
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-057-5804?

NSN 5915-00-057-5804 is a Filter,band Pass, classified under FSC 5915, Filters and Networks. Status: active.

What are the specifications of 5915-00-057-5804?

Key specifications for 5915-00-057-5804: Maximum Dielectric Withstanding DC Voltage: 100.0 VOLTS AT SEA LEVEL; Reference Frequency Per Function: 147.5 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED; Mounting Facility Type and Quantity: 4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED; Overall Height: 1.906 INCHES MAXIMUM IN. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-057-5804 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com