PartsTable TECHNICAL DATA SHEET
NSN 5915-00-016-4200Government record, cited

Filter, Radio Frequency Interfere5915-00-016-4200

NSN 5915-00-016-4200 · NIIN 000164200 · Part number 20-0231-00
Hisonic, Llc · FSC 5915 — Filters and Networks · FSG 59 — Electrical and Electronic Equipment Components · CAGE 11402
Government record, cited
NSN 5915-00-016-4200 — this item is cataloged by the U.S. Government under National Stock Number 5915-00-016-4200. Manufacturer of record part number: 20-0231-00.
Also searched as  5915-00-016-4200 · 5915000164200 · NIIN 000164200 · 00-016-4200 · FSC 5915 Filters and Networks · CAGE 11402 · 20-0231-00 · 673-0757-00 · FC244A · 673-0757-000 · 673-0757-000
Nearby stock numbers  ·
Features
  • Filter,radio Frequency Interfere — FSC 5915
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
  • Inclosure Type: HERMETICALLY SEALED
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.550 INCHES NOMINAL IN
  • Power Line Frequency Rating Per Function in Hertz: 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
  • Power Line Frequency Rating Per Function in Hertz: 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
  • Functional Terminal Type and Quantity: 2 TAB, SOLDER LUG INPUT FIRST FUNCTION
  • Functional Terminal Type and Quantity: 2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Identification
  • NSN: 5915-00-016-4200
  • NIIN: 000164200
  • FSC: 5915 — Filters and Networks
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 20-0231-00
  • Manufacturer: Hisonic, Llc
General Description

The Filter,radio Frequency Interfere, cataloged under National Stock Number 5915-00-016-4200, is classified within Federal Supply Class 5915 (Filters and Networks) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Hisonic, Llc. Government technical data includes 26 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5915-00-016-4200
Primary Part Number20-0231-00
Item NameFilter,radio Frequency Interfere
FSC / FSG5915 / 59 — Filters and Networks
ManufacturerHisonic, Llc
StatusACTIVE
Mounting Facility Type and Quantity2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
Inclosure TypeHERMETICALLY SEALED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.550 INCHES NOMINAL IN
Power Line Frequency Rating Per Function in Hertz400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Power Line Frequency Rating Per Function in Hertz400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Functional Terminal Type and Quantity2 TAB, SOLDER LUG INPUT FIRST FUNCTION
Functional Terminal Type and Quantity2 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
Functional Terminal Type and Quantity1 TAB, SOLDER LUG GROUND THIRD FUNCTION
Source Impedance Rating Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Source Impedance Rating Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Body Width0.530 INCHES NOMINAL IN
Body Height0.925 INCHES NOMINAL IN
Style DesignatorRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
Mounting Facility Screw Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Nominal Thread Size0.112 INCHES IN
Body MaterialMETAL
Body Length2.262 INCHES MAXIMUM IN
Operating Voltage Rating and Type Per Function120.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Voltage Rating and Type Per Function120.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
Principal Circuitry Type Per FunctionINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Current Rating Per Function in Amps5.0 2ND RADIO INTERFERENCE SECOND FUNCTION
Operating Current Rating Per Function in Amps5.0 1ST RADIO INTERFERENCE FIRST FUNCTION
Operating Temp Range-62.0 TO 100.0 CELSIUS DEGC
Load Impedance Per Function50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
Load Impedance Per Function50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
20-0231-00 Hisonic, Llc (USA)
Reference documents
ReferenceMeaning
673-0757-00 5/2 Secondary reference
U.S. Government activity
FC244A 5/9 Secondary reference
U.S. Government activity
673-0757-000 3/2 Design control — primary reference
U.S. Government activity
673-0757-000 5/9 Secondary reference
Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems
TS-5266 5/9 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5915 — Filters and Networks
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5915-00-000-0148
FILTER,BAND PASS
5915-00-001-1389
5915-00-001-1389 · Item name not on file
5915-00-001-1621
FILTER,BAND PASS
5915-00-001-2789
5915-00-001-2789 · Item name not on file
5915-00-001-2928
FILTER,BAND SUPPRESSION
5915-00-001-2936
FILTER,RADIO FREQUENCY INTERFERE
5915-00-001-3003
5915-00-001-3003 · Item name not on file
5915-00-001-3117
FILTER ASSEMBLY,ELECTRICAL

Frequently Asked Questions

What is NSN 5915-00-016-4200?

NSN 5915-00-016-4200 is a Filter,radio Frequency Interfere, manufactured by Hisonic, Llc, classified under FSC 5915, Filters and Networks. Status: active.

What part numbers are listed for NSN 5915-00-016-4200?

NSN 5915-00-016-4200 has 1 manufacturer part number on file: 20-0231-00 (Hisonic, Llc).

What are the specifications of 20-0231-00?

Key specifications for 20-0231-00: Mounting Facility Type and Quantity: 2 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED; Inclosure Type: HERMETICALLY SEALED; Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 2.550 INCHES NOMINAL IN; Power Line Frequency Rating Per Function in Hertz: 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5915-00-016-4200 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com