The Capacitor,fixed,ceramic Dielectr, cataloged under National Stock Number 5910-00-782-7133, is classified within Federal Supply Class 5910 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems. Government technical data includes 18 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 10 commercial cross-references from 9 manufacturers, enabling identification through both NSN and commercial part number lookups. 12 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5910-00-782-7133 |
| Primary Part Number | 913-4174-000 |
| Item Name | Capacitor,fixed,ceramic Dielectr |
| FSC / FSG | 5910 / 59 — No Item Name Available |
| Manufacturer | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems |
| Status | CANCELLED |
| Voltage Temp Limits Per Section in Percent Capacitance Change | -30.0 TO 10.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION |
| Terminal Type and Quantity | 2 UNINSULATED WIRE LEAD |
| Body Diameter | 0.930 INCHES NOMINAL IN |
| Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
| Capacitance Value Per Section | 10000.000 PICOFARADS SINGLE SECTION |
| Body Length | 0.250 INCHES NOMINAL IN |
| Nonderated Operating Temp | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM DEGC |
| Center to Center Distance Between Terminals Parallel to Diameter | 0.375 INCHES NOMINAL IN |
| Nonderated Continuous Voltage Rating and Type Per Section | 3000.0 DC SINGLE SECTION |
| Terminal Length | 1.250 INCHES MINIMUM IN |
| Tolerance Range Per Section | -20.00 TO 20.00 PERCENT SINGLE SECTION |
| Terminal Diameter | 0.025 INCHES NOMINAL IN |
| Material | PLASTIC CASE |
| Insulation Resistance at Reference Temp | 50000.0 MEGOHMS |
| Terminal Surface Treatment | SOLDER |
| Dissipation Factor at Reference Temp in Percent | 2.0000 |
| Reliability Indicator | NOT ESTABLISHED |
| Body Style | W/O MTG FACILITIES, RADIAL TERMINALS |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 600511 | Canberra Industries Inc. (USA) |
| 77500 | Sprague Electric Co World Hqs (USA) |
| 0309210-2 | Navy, United States Department of the Spawar Dba Space and Naval Wafare Command (USA) |
| 564CZ5UAA302EM103M | Cera-Mite Corp (USA) |
| 30GA-S10 | Veeco Instruments Inc Lambda Div (USA) |
| 913-4174-000 PRIMARY | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems (USA) |
| 136-0107 | Autek Systems Corp (USA) |
| 106930 | Fluke Corp (USA) |
| 564CZ5UAA302EP103M | Cera-Mite Corp (USA) |
| 30GA-S10 | Sprague Products Co (USA) |
NSN 5910-00-782-7133 is a Capacitor,fixed,ceramic Dielectr, manufactured by Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems, classified under FSC 5910 (No Item Name Available). Status: cancelled.
NSN 5910-00-782-7133 has 10 cross-referenced part numbers: 600511 (Canberra Industries Inc.), 77500 (Sprague Electric Co World Hqs), 0309210-2 (Navy, United States Department of the Spawar Dba Space and Naval Wafare Command), 564CZ5UAA302EM103M (Cera-Mite Corp), 30GA-S10 (Veeco Instruments Inc Lambda Div) and 5 more.
There are 12 known substitutes for 5910-00-782-7133: 3110-00-144-8869, 5945-00-688-6942, 5342-00-722-1993 and 9 more. Verify interchangeability with system specifications before substitution.
Key specifications for 913-4174-000: Voltage Temp Limits Per Section in Percent Capacitance Change: -30.0 TO 10.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION; Terminal Type and Quantity: 2 UNINSULATED WIRE LEAD; Body Diameter: 0.930 INCHES NOMINAL IN; Schematic Diagram Designator: NO COMMON OR GROUNDED ELECTRODE(S). 18 total characteristics are documented in the Federal Logistics Information System.
NSN 5910-00-782-7133 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.