The Capacitor,fixed,ceramic Dielectr, cataloged under National Stock Number 5910-00-660-7496, is classified within Federal Supply Class 5910 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Lockheed Martin Corporation Div Rms - Mitchel Field. Government technical data includes 16 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 15 commercial cross-references from 11 manufacturers, enabling identification through both NSN and commercial part number lookups. 5 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Cancelled.
| Parameter | Value |
|---|---|
| NSN | 5910-00-660-7496 |
| Primary Part Number | 2578105-02 |
| Item Name | Capacitor,fixed,ceramic Dielectr |
| FSC / FSG | 5910 / 59 — No Item Name Available |
| Manufacturer | Lockheed Martin Corporation Div Rms - Mitchel Field |
| Status | CANCELLED |
| Terminal Diameter | 0.016 INCHES NOMINAL IN |
| Body Diameter | 0.120 INCHES NOMINAL IN |
| Capacitance Value Per Section | 5000.000 PICOFARADS SINGLE SECTION |
| Tolerance Range Per Section | -20.00 TO 20.00 PERCENT SINGLE SECTION |
| Nonderated Operating Temp | -55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM DEGC |
| Voltage Temp Limits Per Section in Percent Capacitance Change | -82.0 TO 22.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |
| Terminal Length | 1.500 INCHES MINIMUM IN |
| Body Length | 0.500 INCHES NOMINAL IN |
| Schematic Diagram Designator | NO COMMON OR GROUNDED ELECTRODE(S) |
| Nonderated Continuous Voltage Rating and Type Per Section | 100.0 DC SINGLE SECTION |
| Terminal Surface Treatment | SOLDER |
| Case Insulation Material | PLASTIC |
| Terminal Type and Quantity | 2 UNINSULATED WIRE LEAD |
| Insulation Resistance at Reference Temp | 10000.0 MEGOHMS |
| Body Style | W/O MTG FACILITIES, AXIAL TERMINALS |
| Reliability Indicator | NOT ESTABLISHED |
| Acquisition Status | CANCELLED |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 2578105-02 | Lockheed Martin Corporation Div Rms - Mitchel Field (USA) |
| 414-150-034 | Safran (FRA) |
| 414-00150-034 | Sfim Industries (FRA) |
| 414-00150-034 | Safran Electronics & Defense (FRA) |
| 414-150-034 | Safran Electronics & Defense (FRA) |
| 117981 | Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA) |
| 244004-50 | Mas Components & Coatings, Llc Dba Mas Components & Coatings Llc (USA) |
| 414-00150-034 | Safran (FRA) |
| 913-3020-00 | Rockwell Collins, Inc. Dba Collins Aerospace Government Systems Div Collins Aerospace - Government Systems (USA) |
| 913-3020-000 | Rockwell Collins, Inc. Div Collins Aerospace - Mission Systems (USA) |
| 21327-10 | Northrop Grumman Corp Precision Products Plant (USA) |
| 414-150-034 | Sfim Industries (FRA) |
| 244004-50 | Alliant Defense Electronics Systems Inc Dba Lundy Technical Center (USA) |
| 1778335-02 | Lockheed Martin Corporation Div Rms - Mitchel Field (USA) |
| MC80V502AM | Aerovox Corp. (USA) |
NSN 5910-00-660-7496 is a Capacitor,fixed,ceramic Dielectr, manufactured by Lockheed Martin Corporation Div Rms - Mitchel Field, classified under FSC 5910 (No Item Name Available). Status: cancelled.
NSN 5910-00-660-7496 has 15 cross-referenced part numbers: 2578105-02 (Lockheed Martin Corporation Div Rms - Mitchel Field), 414-150-034 (Safran), 414-00150-034 (Sfim Industries), 414-00150-034 (Safran Electronics & Defense), 414-150-034 (Safran Electronics & Defense) and 10 more.
There are 5 known substitutes for 5910-00-660-7496: 5826-00-091-1396, 5998-00-155-4300, 5935-00-903-8498 and 2 more. Verify interchangeability with system specifications before substitution.
Key specifications for 2578105-02: Terminal Diameter: 0.016 INCHES NOMINAL IN; Body Diameter: 0.120 INCHES NOMINAL IN; Capacitance Value Per Section: 5000.000 PICOFARADS SINGLE SECTION; Tolerance Range Per Section: -20.00 TO 20.00 PERCENT SINGLE SECTION. 16 total characteristics are documented in the Federal Logistics Information System.
NSN 5910-00-660-7496 is currently cancelled. Check with the Defense Logistics Agency for current availability and authorized substitutes.