The Resistor Network,fixed,film, cataloged under National Stock Number 5905-01-250-3275, is classified within Federal Supply Class 5905 (Resistor) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Technical Communications Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5905-01-250-3275 |
| Primary Part Number | 301938-00E |
| Item Name | Resistor Network,fixed,film |
| FSC / FSG | 5905 / 59 — Resistor |
| Manufacturer | Technical Communications Corp |
| Status | ACTIVE |
| Resistance Tolerance in Percent | -1.000 TO 1.000 EACH RESISTOR |
| Temp Coefficient of Resistance in Ppm Per Deg Celsius | -50.0 TO 50.0 LOCATION NOT OTHERWISE SPECIFIED |
| Electrical Resistance | 5.000 KILOHMS LOWEST RESISTANCE VALUE |
| Electrical Resistance | 500.000 KILOHMS HIGHEST RESISTANCE VALUE |
| Electrical Resistance | 150.000 KILOHMS SECOND INTERMEDIATE RESISTANCE VALUE |
| Electrical Resistance | 230.000 KILOHMS THIRD INTERMEDIATE RESISTANCE VALUE |
| Electrical Resistance | 33.000 KILOHMS FIRST INTERMEDIATE RESISTANCE VALUE |
| Terminal Quantity | 10 |
| Terminal Type | PIN |
| Identical Value Resistor Quantity | 2 HIGHEST RESISTANCE VALUE |
| Identical Value Resistor Quantity | 1 SECOND INTERMEDIATE RESISTANCE VALUE |
| Identical Value Resistor Quantity | 1 LOWEST RESISTANCE VALUE |
| Identical Value Resistor Quantity | 2 THIRD INTERMEDIATE RESISTANCE VALUE |
| Identical Value Resistor Quantity | 1 FIRST INTERMEDIATE RESISTANCE VALUE |
| Inclosure Method | ENCAPSULATED |
| Terminal Length | 0.125 INCHES NOMINAL IN |
| Body Width | 0.290 INCHES MAXIMUM IN |
| Body Height | 0.170 INCHES MAXIMUM IN |
| Temp Range of Temp Coefficient in Deg Celsius | -55.0 TO 125.0 LOCATION NOT OTHERWISE SPECIFIED |
| Style Designator | SINGLE INLINE |
| Reliability Failure Rate Level in Percent | 0.100 |
| Power Dissipation Rating in Watts | 1.000 TOTAL NETWORK LOCATION NOT OTHERWISE SPECIFIED |
| Schematic Diagram Designator | LADDER NETWORK |
| Body Length | 1.000 INCHES NOMINAL IN |
| Ambient Temp in Deg Celsius at Zero Percent Rated Power | 125.0 |
| Reliability Indicator | ESTABLISHED |
| Cubic Measure | 0.036 CUBIC INCHES |
| Ambient Temp in Deg Celsius at Full Rated Power | 70.0 |
| Test Data Document | 82577-655794 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| Terminal Width | 0.020 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | No hazard code in the DLA record (HMIC N) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 301938-00E | Technical Communications Corp (USA) |
| 301938-00E | Vishay Sprague, Inc. Dba Vishay Electro-Films Inc. Div Vishay Electro-Films (USA) |
| Reference | Meaning |
|---|---|
| 655794-05 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5905-01-250-3275 is a Resistor Network,fixed,film, manufactured by Technical Communications Corp, classified under FSC 5905, Resistor. Status: active.
NSN 5905-01-250-3275 has 2 manufacturer part numbers on file: 301938-00E (Technical Communications Corp), 301938-00E (Vishay Sprague, Inc. Dba Vishay Electro-Films Inc. Div Vishay Electro-Films).
Key specifications for 301938-00E: Resistance Tolerance in Percent: -1.000 TO 1.000 EACH RESISTOR; Temp Coefficient of Resistance in Ppm Per Deg Celsius: -50.0 TO 50.0 LOCATION NOT OTHERWISE SPECIFIED; Electrical Resistance: 5.000 KILOHMS LOWEST RESISTANCE VALUE; Electrical Resistance: 500.000 KILOHMS HIGHEST RESISTANCE VALUE. 30 specifications are documented in the U.S. Government catalog.
No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.