PartsTable TECHNICAL DATA SHEET
NSN 5905-01-103-4705Government record, cited

Resistor, Variable, Nonwire Wound,5905-01-103-4705

NSN 5905-01-103-4705 · NIIN 011034705 · Part number 3110346
Fluke Biomedical Corporation · FSC 5905 — Resistor · FSG 59 — Electrical and Electronic Equipment Components · CAGE 34511
Government record, cited
NSN 5905-01-103-4705 — this item is cataloged by the U.S. Government under National Stock Number 5905-01-103-4705. Manufacturer of record part number: 3110346.
Also searched as  5905-01-103-4705 · 5905011034705 · NIIN 011034705 · 01-103-4705 · FSC 5905 Resistor · CAGE 34511 · 3110346 · 803506-501 · 375Y501B
Nearby stock numbers  ·
Features
  • Resistor,variable,nonwire Wound, — FSC 5905
  • Maximum Running Torque: 6.00 INCH-OUNCES IN
  • Body Diameter: 0.370 INCHES NOMINAL IN
  • Electrical Resistance Per Section: 500.000 OHMS SINGLE SECTION
  • Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power: 125.0 SINGLE SECTION
  • Section Quantity: 1
  • Body Style: CYLINDRICAL
  • Terminal Length: 0.187 INCHES MINIMUM IN
Identification
  • NSN: 5905-01-103-4705
  • NIIN: 011034705
  • FSC: 5905 — Resistor
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 3110346
  • Manufacturer: Fluke Biomedical Corporation
General Description

The Resistor,variable,nonwire Wound,, cataloged under National Stock Number 5905-01-103-4705, is classified within Federal Supply Class 5905 (Resistor) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Fluke Biomedical Corporation. Government technical data includes 23 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5905-01-103-4705
Primary Part Number3110346
Item NameResistor,variable,nonwire Wound,
FSC / FSG5905 / 59 — Resistor
ManufacturerFluke Biomedical Corporation
StatusACTIVE
Maximum Running Torque6.00 INCH-OUNCES IN
Body Diameter0.370 INCHES NOMINAL IN
Electrical Resistance Per Section500.000 OHMS SINGLE SECTION
Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power125.0 SINGLE SECTION
Section Quantity1
Body StyleCYLINDRICAL
Terminal Length0.187 INCHES MINIMUM IN
Mounting MethodTERMINAL
Maximum Starting Torque6.00 INCH-OUNCES IN
Temp Coefficient of Resistance Per Section in Ppm Per Deg Celsius-100.0 TO 100.0 SINGLE SECTION
Terminal LocationREAR END
Center to Center Distance Between Center Terminal and Outside Terminal0.100 INCHES NOMINAL IN
Actuator TypeINTEGRAL KNOB
Body Length0.250 INCHES MAXIMUM IN
Center to Center Distance Between Terminals0.200 INCHES NOMINAL IN
Power Dissipation Rating Per Section in Watts1.0 FREE AIR SINGLE SECTION
Effective Electrical Rotation in Deg Angular Rotation205.0 NOMINAL
Reliability IndicatorNOT ESTABLISHED
Actuator Travel Control FeatureSTOPS
Resistance Tolerance Per Section in Percent-20.0 TO 20.0 SINGLE SECTION
Terminal Type and Quantity3 PIN
Rotary Actuator Travel in Angular Deg205.0 NOMINAL
Ambient Temp in Deg Celsius Per Section at Full Rated Power40.0 SINGLE SECTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
3950-01-657-1929 POSSIBLE MATCH
WINCH,DRUM,HAND OPERATED
Possible match (shared part number)
Cross-Reference Index
Part NumberManufacturer
803506-501 Evans & Sutherland Computer Corp (USA)
3110346 PRIMARY Fluke Biomedical Corporation (USA)
Reference documents
ReferenceMeaning
375Y501B 5/9 Secondary reference
Cts of West Liberty Inc
Related Parts
3950-01-657-1929POSSIBLE MATCH
WINCH,DRUM,HAND OPERATED

Frequently Asked Questions

What is NSN 5905-01-103-4705?

NSN 5905-01-103-4705 is a Resistor,variable,nonwire Wound,, manufactured by Fluke Biomedical Corporation, classified under FSC 5905, Resistor. Status: active.

What part numbers are listed for NSN 5905-01-103-4705?

NSN 5905-01-103-4705 has 2 manufacturer part numbers on file: 803506-501 (Evans & Sutherland Computer Corp), 3110346 (Fluke Biomedical Corporation).

What NSN replaces 5905-01-103-4705?

1 possible match (shared part number, not a government interchangeability claim): 3950-01-657-1929. Verify interchangeability with system specifications before substitution.

What are the specifications of 3110346?

Key specifications for 3110346: Maximum Running Torque: 6.00 INCH-OUNCES IN; Body Diameter: 0.370 INCHES NOMINAL IN; Electrical Resistance Per Section: 500.000 OHMS SINGLE SECTION; Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power: 125.0 SINGLE SECTION. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5905-01-103-4705 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com