PartsTable TECHNICAL DATA SHEET
NSN 5905-01-082-9499Government record, cited

Resistor, Variable, Nonwire Wound,5905-01-082-9499

NSN 5905-01-082-9499 · NIIN 010829499 · Part number 3110347
Fluke Biomedical Corporation · FSC 5905 — Resistor · FSG 59 — Electrical and Electronic Equipment Components · CAGE 34511
Government record, cited
NSN 5905-01-082-9499 — this item is cataloged by the U.S. Government under National Stock Number 5905-01-082-9499. Manufacturer of record part number: 3110347.
Also searched as  5905-01-082-9499 · 5905010829499 · NIIN 010829499 · 01-082-9499 · FSC 5905 Resistor · CAGE 34511 · 3110347 · 375Y102B · 803506-102
Nearby stock numbers  ·
Features
  • Resistor,variable,nonwire Wound, — FSC 5905
  • Maximum Running Torque: 6.00 INCH-OUNCES IN
  • Body Diameter: 0.370 INCHES NOMINAL IN
  • Electrical Resistance Per Section: 1.000 KILOHMS SINGLE SECTION
  • Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power: 125.0 SINGLE SECTION
  • Section Quantity: 1
  • Body Style: CYLINDRICAL
  • Terminal Length: 0.187 INCHES MINIMUM IN
Identification
  • NSN: 5905-01-082-9499
  • NIIN: 010829499
  • FSC: 5905 — Resistor
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 3110347
  • Manufacturer: Fluke Biomedical Corporation
General Description

The Resistor,variable,nonwire Wound,, cataloged under National Stock Number 5905-01-082-9499, is classified within Federal Supply Class 5905 (Resistor) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Fluke Biomedical Corporation. Government technical data includes 23 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5905-01-082-9499
Primary Part Number3110347
Item NameResistor,variable,nonwire Wound,
FSC / FSG5905 / 59 — Resistor
ManufacturerFluke Biomedical Corporation
StatusACTIVE
Maximum Running Torque6.00 INCH-OUNCES IN
Body Diameter0.370 INCHES NOMINAL IN
Electrical Resistance Per Section1.000 KILOHMS SINGLE SECTION
Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power125.0 SINGLE SECTION
Section Quantity1
Body StyleCYLINDRICAL
Terminal Length0.187 INCHES MINIMUM IN
Mounting MethodTERMINAL
Maximum Starting Torque6.00 INCH-OUNCES IN
Temp Coefficient of Resistance Per Section in Ppm Per Deg Celsius-100.0 TO 100.0 SINGLE SECTION
Terminal LocationREAR END
Center to Center Distance Between Center Terminal and Outside Terminal0.100 INCHES NOMINAL IN
Actuator TypeINTEGRAL KNOB
Body Length0.220 INCHES MAXIMUM IN
Center to Center Distance Between Terminals0.200 INCHES NOMINAL IN
Power Dissipation Rating Per Section in Watts1.0 FREE AIR SINGLE SECTION
Effective Electrical Rotation in Deg Angular Rotation205.0 NOMINAL
Reliability IndicatorNOT ESTABLISHED
Actuator Travel Control FeatureSTOPS
Resistance Tolerance Per Section in Percent-20.0 TO 20.0 SINGLE SECTION
Terminal Type and Quantity3 PIN
Rotary Actuator Travel in Angular Deg205.0 NOMINAL
Ambient Temp in Deg Celsius Per Section at Full Rated Power40.0 SINGLE SECTION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardNo hazard code in the DLA record (HMIC N)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
3110347 PRIMARY Fluke Biomedical Corporation (USA)
803506-102 Evans & Sutherland Computer Corp (USA)
Reference documents
ReferenceMeaning
375Y102B 5/9 Secondary reference
Cts Corp of California Dba Cts Electronics Corp Paso Robles Div Electromechanical Group
No interchangeability data on file.
Other items in FSC 5905 — Resistor
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5905-00-000-0136
RESISTOR NETWORK,FIXED,FILM
5905-00-000-0488
5905-00-000-0488 · Item name not on file
5905-00-000-8809
5905-00-000-8809 · Item name not on file
5905-00-000-8833
5905-00-000-8833 · Item name not on file
5905-00-000-9526
5905-00-000-9526 · Item name not on file
5905-00-001-1342
5905-00-001-1342 · Item name not on file
5905-00-001-1573
5905-00-001-1573 · Item name not on file
5905-00-001-2059
5905-00-001-2059 · Item name not on file

Frequently Asked Questions

What is NSN 5905-01-082-9499?

NSN 5905-01-082-9499 is a Resistor,variable,nonwire Wound,, manufactured by Fluke Biomedical Corporation, classified under FSC 5905, Resistor. Status: active.

What part numbers are listed for NSN 5905-01-082-9499?

NSN 5905-01-082-9499 has 2 manufacturer part numbers on file: 3110347 (Fluke Biomedical Corporation), 803506-102 (Evans & Sutherland Computer Corp).

What are the specifications of 3110347?

Key specifications for 3110347: Maximum Running Torque: 6.00 INCH-OUNCES IN; Body Diameter: 0.370 INCHES NOMINAL IN; Electrical Resistance Per Section: 1.000 KILOHMS SINGLE SECTION; Ambient Temp in Deg Celsius Per Section at Zero Percent Rated Power: 125.0 SINGLE SECTION. 23 specifications are documented in the U.S. Government catalog.

Is NSN 5905-01-082-9499 hazardous material?

No hazard code in the DLA record (HMIC N). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com